SHERWIN-WILLIAMS CO -- B33W203 DEEPTONE BASE, PROMAR 200 ALKYD (SUP DAT) -- 8010-00N085123 ======================================================= MSDS Safety Information ======================================================= FSC: 8010 MSDS Date: 11/01/1995 MSDS Num: CGZZS LIIN: 00N085123 Tech Review: 01/28/2002 Product ID: B33W203 DEEPTONE BASE, PROMAR 200 ALKYD (SUP DAT) Responsible Party Cage: 54636 Name: SHERWIN-WILLIAMS CO Address: 101 PROSPECT AVE NW City: CLEVELAND OH 44115 US Info Phone Number: 216-566-2902 Emergency Phone Number: 216-566-2917 Review Ind: N ======================================================= Contractor Summary ======================================================= Cage: 54636 Name: SHERWIN-WILLIAMS CO THE Address: 101 PROSPECT AVE NW City: CLEVELAND OH 44115-1042 US Phone: 800-251-2486/216-566-2242 ======================================================= Ingredients ======================================================= Cas: 107-21-1 RTECS #: KW2975000 Name: ETHYLENE GLYCOL (SARA 313) (CERCLA) VP: 0.1 % by Wt: <5 OSHA PEL: C 50 PPM (MFR) ACGIH TLV: C 50 PPM, VAPOR EPA Rpt Qty: 1 LB DOT Rpt Qty: 1 LB Ozone Depleting Chemical: N ------------------------------ Cas: 64742-88-7 RTECS #: WF3450000 Name: SOLVENT NAPHTHA, PETROLEUM, MEDIUM ALIPHATIC; (MINERAL SPIRITS) VP: 2.0 % by Wt: 32-35 OSHA PEL: 100 PPM (MFR) ACGIH TLV: 100 PPM (MFR) Ozone Depleting Chemical: N ------------------------------ Cas: 64742-88-7 RTECS #: WF3450000 Name: SOLVENT NAPHTHA, PETROLEUM, MEDIUM ALIPHATIC; (MINERAL SPIRITS 140-FLASH) VP: 0.5 % by Wt: 32-35 OSHA PEL: 100 PPM (MFR) ACGIH TLV: 100 PPM (MFR) Ozone Depleting Chemical: N ------------------------------ Cas: 14807-96-6 RTECS #: WW2710000 Name: TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC) % by Wt: 0-8 OSHA PEL: 20 MPPCF ACGIH TLV: 2 MG/M3 RDUST Ozone Depleting Chemical: N ------------------------------ Cas: 471-34-1 RTECS #: FF9335000 Name: CARBONIC ACID, CALCIUM SALT (1:1); (CALCIUM CARBONATE) % by Wt: 8-25 OSHA PEL: 15.5 MG/M3 (MFR) ACGIH TLV: 10 MG/M3 (MFR) Ozone Depleting Chemical: N ------------------------------ Cas: 13463-67-7 RTECS #: XR2275000 Name: TITANIUM OXIDE; (TITANIUM DIOXIDE) % by Wt: 10-27 OSHA PEL: 15 MG/M3 TDUST ACGIH TLV: 10 MG/M3 TDUST Ozone Depleting Chemical: N ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER. Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: NO Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: ACUTE: IRRIT OF EYES, SKIN & RESP SYS. MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON & POSS DEATH. SIGNS & SYMPS OF OVEREXP: HDCH, DIZZ, NAUS, & LOSS OF COORD ARE INDICATIONS OF EXCESS EXPOS TO VAPS/SPRAY MISTS. REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESS SKIN EXPOS. (EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT. Signs And Symptions Of Overexposure: HLTH HAZ: ETHYLENE GLYCOL IS CONSIDERED AN ANIMAL TERATOGEN. IF HAS BEEN SHOWN TO CAUSE BIRTH DEFECTS IN RATS & MICE AT HIGH DOSES WHEN GIVEN IN DRINKING WATER/BY GAVAGE. THERE IS NO EVIDENCE TO INDIC ATE IT CAUSES BIRTH DEFECTS IN HUMANS. PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS TO LIVER & URINARY SYS. RATS EXPOSED TO TITANIUM DIOXIDE DUST AT 250 MG/M3 DEVELOPED LUNG CANCER, HOWEVER, SUCH EXPOS LEVELS ARE NOT ATTAINABLE IN WORKPLACE. RPTS HAVE ASSOC RPTD/PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. Medical Cond Aggravated By Exposure: NONE GENERALLY RECOGNIZED. First Aid: INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM AND QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. EYES: FLUSH WI TH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGESTION: GET MEDICAL ATTENTION. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION. VENTILATE AND REMOVE WITH INERT ABSORBENT. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: WASTE MAY BE HAZ AS DEFINED UNDER RCRA 40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE APPLIC EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD CONTR. DISP OF I/A/W FED , STATE, & LOC REGS REGARDING POLLUTION. Handling And Storage Precautions: USE ONLY W/ADEQUATE VENTILATION. AVOID BREATHING VAP & SPRAY MIST. AVOID CONTACT W/SKIN & EYES. KEEP AWAY FROM HEAT & OPEN FLAME. CONSULT NFPA CODE. Other Precautions: USE APPRVD BONDING & GROUNDING PROC. KEEP CONTR CLSD WHEN NOT IN USE. TRANSFER ONLY TO APPRVD CONTRS W/COMPLETE & APPROP LABELING. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN. INTENTIONAL MI SUSE BY DELIB CONCENTRATING & INHALING CONTENTS CAN BE HARMFUL/FATAL. THESE COATINGS MAY CONTAIN MAT LS (SUPDAT) ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: 102F,39C Lower Limits: 1.0% Upper Limits: 7.0% Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL, FOAM. Fire Fighting Procedures: WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP (FP N). IF WATER IS USED, FOG NOZZ ARE PREF. WATER MAY BE USED TO COOL CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. Unusual Fire/Explosion Hazard: KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM HEAT, ELEC EQUIP, SPKS, & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. APPLICATION TO HOT SURFS REQUIRES SPECIAL PREC. DURING EMER CNDTNS OV EREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN. ======================================================= Control Measures ======================================================= Respiratory Protection: IF PERS EXPOS CANNOT BE CONTROLLED BELOW APPLIC LIMS BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP APPRVD BY NIOSH FOR PROT. WHEN SANDING/ABRADING DRIED FILM, WEAR DUST/MIST RESP APPRVD BY NI OSH FOR DUST WHICH MAY BE GENERATED FROM THIS PROD, UNDERLYING PAINT/ABRASIVE. Ventilation: LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINT < APPLIC EXPOS LIMS. REFER TO OSHA STDS 1910.94, 1910.107/108. Protective Gloves: IMPERVIOUS GLOVES (FP N). Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N). Other Protective Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). Work Hygienic Practices: WASH HANDS AFTER USE. Supplemental Safety and Health: TRADE NAME/PART #:INTERIOR FINISHES. OTHER PRECS: CLASSIFIED AS NUISANCE PARTICULATES WHICH MAY BE PRESENT AT HAZARDOUS LEVELS ONLY DURING SANDING OR ABRADING OF THE DRIED FILM. ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: >300F,>149C Vapor Pres: SEE INGS Vapor Density: HVR/AIR Spec Gravity: 0.82-1.80 VOC Pounds/Gallon: 3.62 Evaporation Rate & Reference: SLOWER THAN ETHER Appearance and Odor: NONE SPECIFIED BY MANUFACTURER Percent Volatiles by Volume: 29-90 ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER. Materials To Avoid: NONE KNOWN. Hazardous Decomposition Products: BY FIRE: CARBON DIOXIDE, CARBON MONOXIDE. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT. ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= Other Information: VOLATILE ORGANIC COMPOUND: 3.52-3.62 LBS/GAL. ======================================================= HAZCOM Label ======================================================= Product ID: B33W203 DEEPTONE BASE, PROMAR 200 ALKYD (SUP DAT) Cage: 54636 Company Name: SHERWIN-WILLIAMS CO THE Street: 101 PROSPECT AVE NW City: CLEVELAND OH Zipcode: 44115-1042 US Health Emergency Phone: 216-566-2917 Date Of Label Review: 04/21/1998 Label Date: 04/21/1998 Chronic Hazard IND: Y Eye Protection IND: YES Skin Protection IND: YES Signal Word: WARNING Respiratory Protection IND: YES Health Hazard: Moderate Contact Hazard: Moderate Fire Hazard: Moderate Reactivity Hazard: None Hazard And Precautions: COMBUSTIBLE. ACUTE: IRRITATION OF EYES, SKIN AND RESPIRATORY SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. EXTREME OVEREXPOSURE MAY RESULT IN UNCONSCIOUSNESS AND POSSIBLY DEATH. SIGNS AND SYMPTOMS OF O VEREXPOSURE: HEADACHE, DIZZINESS, NAUSEA, AND LOSS OF COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS OR SPRAY MISTS. REDNESS AND ITCHING OR BURNING SENSATION MAY INDICATE EYE OR EXCESSIV E SKIN EXPOSURE. CHRONIC: ETHYLENE GLYCOL IS CONSIDERED AN ANIMAL TERATOGEN. BIRTH DEFECTS POSSIBLE. ADVERSE EFFECTS TO LIVER AND URINARY SYSTEMS. POSSIBLE LUNG CANCER. POSSIBLE PERMANENT BRAIN AND NE RVOUS SYSTEM DAMAGE. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.