C M ATHEY PAINT CO -- KRYSTLAC EN WHITE, FBM70 ======================================================= MSDS Safety Information ======================================================= FSC: 8010 MSDS Date: 05/22/1989 MSDS Num: BSGQG LIIN: 00N040448 Product ID: KRYSTLAC EN WHITE, FBM70 MFN: 01 Responsible Party Cage: 84205 Name: C M ATHEY PAINT CO Address: 1809 BAYARD ST City: BALTIMORE MD 21230 Info Phone Number: 301-727-3822 Emergency Phone Number: 301-727-3823 Published: Y ======================================================= Contractor Summary ======================================================= Cage: 84205 Name: C M ATHEY PAINT CO Address: 1809 BAYARD ST City: BALTIMORE MD 21230 Phone: 301-727-3822 ======================================================= Ingredients ======================================================= Cas: 8052-41-3 RTECS #: WJ8925000 Name: STODDARD SOLVENT; (MINERAL SPIRIT). VP: 0.10. LEL: 1% % Wt: 37.63 OSHA PEL: 100 PPM ACGIH TLV: 100 PPM ------------------------------ Cas: 13463-67-7 RTECS #: XR2275000 Name: TITANIUM OXIDE; (TITANIUM DIOXIDE) % Wt: 4.06 OSHA PEL: 10 MG/M3 TDUST ACGIH TLV: 10 MG/M3 TDUST ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER. Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: NO Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: ACUTE: INHAL: IRRIT OF RESP TRACT/ACUTE NERV SYS DEPRESS CHARACT BY FOLLOWING STEPS: HDCH, DIZZ, STAGGER, CONFUSN/COMA. SKIN/EYE CONT: PRIMARY IRRITATION OR SENSITIZER. HEALTH STUDIES HAVE SHOWN THAT PETROLEUM HYDROCARBONS POSE POTENTIAL HEALTH RISKS WHICH MAY VARY FROM PERSON TO PERSON. AS A PREC, (EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT Signs And Symptions Of Overexposure: HLTH HAZ: EXPOSURE TO LIQUIDS AND VAPORS OF PETROLEUM PRODUCTS SHOULD BE MINIMIZED. Medical Cond Aggravated By Exposure: INHALATION BY PERSONS WITH RESPIRATORY PROBLEMS COULD HAVE CONDITION ADDITIONALLY AGGRAVATED. First Aid: INHAL:REMOVE TO FRESH AIR. RESTORE BRTHG, TREAT SYMPTOMATICALLY. CONSULT PHYS. EYES: FLUSH IMMED WITH LARGE AMTS OF WATER FOR @ LST 15 MINUTES. CONSULT PHYS. SKIN: WASH AFFECTED AREAS WITH SOAP & WATE R. REMOVE CONTAMD CLOTHING. CONSULT PHYS IF IRRITATION PERSISTS. INGEST: DRINK 1-2 GLASSES OF WATER TO DILUTE. DO NOT INDUCE VOMIT. CONSULT PHYSICIAN OR POIS CTL CTR IMMED. TREAT SYMPTOMATICALLY. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: REMOVE SOURCES OF IGNIT & PROVIDE VENT. USE SCOOP ON LARGE SPILLS AND ABSORBENT MATERIAL ON SMALL SPILLS. AVOID BREATHING VAPOR AND USE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION. FLUSH AREA WITH WATE R. HOLD CLEAN-UP MATLS FOR PROPER DISPOSAL. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: DISPOSAL SHOULD BE DONE I/A/W FEDERAL, STATE, AND LOCAL REGULATIONS. BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZARD CAUTION INFORMATION IN OTHER SECTIONS OF THIS SHEET. Handling And Storage Precautions: STORE AWAY FROM HEAT, SPARKS, & OPEN FLAME IN WELL VENTILATED AREA. DO NOT STORE ABOVE 100F. KEEP CLOSURE TIGHT & CONTAINER UPRIGHT TO PVNT LEAKAGE. Other Precautions: DO NOT GET IN EYES. AVOID SKIN CONT. PVNT PRLNGD/RPTD BRTHG OF VAP/SPRAY MIST. DRUMS SHOULD BE GROUNDED WHEN POURING. RESTRICT FREE-FALL OF LIQ TO A FEW INCHES TO AVOID GENERATION OF STATIC CHARGE. DO NOT PUNCTURE, DRAG/SLIDE CONTAINERS. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: 104F,40C Lower Limits: SEE INGRED Extinguishing Media: FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG. USE ANY CLASS B APPROVED FIR EXTINGUISHER. Fire Fighting Procedures: NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP(FP N). WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE PREF. WATER MAY BE USED TO COOL CONTRS (SUPP DATA) Unusual Fire/Explosion Hazard: KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM HEAT, ELEC EQUIP, SPARKS, & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. APPLICATN TO (SUPP DATA) ======================================================= Control Measures ======================================================= Respiratory Protection: UNRESTRICTED VENT: NIOSH/MSHA APPRVD MECH FILTER TO REMOVE SOLID PARTICALS. RESTRICTED VENT: USE NIOSH/MSHA APPRVD CHEM/MECH FILTER TO REMOVE BOTH VAP & SOLIDS. NO VENT: USE NIOSH/MSHA APPRVD AIR LINE TYPE RESPIRATOR. Ventilation: DESIGNED & MAINTAINED TO PROVIDE VOL & PATTERN TO KEEP CONC IN EXCESS OF TLV.REMOVE DECOMP PROD DURING WELD/ (SUPP DATA) Protective Gloves: NEOPRENE OR OTHER IMPERVIOUS TYPE. Eye Protection: ANSI APRV CHEMICAL WORKERS GOGGLES (FP N Other Protective Equipment: HAVE EYE WASH STATION AND SAFETY SHOWERS AVAILABLE. Work Hygienic Practices: WASH HANDS BEFORE EATING OR USING WASHROOM. SMOKE IN DESIGNATED AREAS ONLY. Supplemental Safety and Health: FIRE FIGHT PROC: TO PVNT PRESS BUILD-UP & EXPLO. EXPLO HAZ: HOT SURF REQ SPEC PREC. VENT: BURNING OF THIS PRODUCT. ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: >317F,>158C Vapor Pres: SEE INGRED Vapor Density: HVR/AIR Evaporation Rate & Reference: SLOWER THAN ETHER Appearance and Odor: NONE SPECIFIED BY MANUFACTURER. Percent Volatiles by Volume: 57.65 ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: HEAT AND OPEN FLAME. Materials To Avoid: OXIDIZING AGENTS. Hazardous Decomposition Products: CARBON MONOXIDE AND OTHER ORGANIC COMPOUNDS MAY BE FORMED DURING COMBUSTION. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= HAZCOM Label ======================================================= Product ID: KRYSTLAC EN WHITE, FBM70 Cage: 84205 Company Name: C M ATHEY PAINT CO Street: 1809 BAYARD ST City: BALTIMORE MD Zipcode: 21230 Health Emergency Phone: 301-727-3823 Label Required IND: Y Date Of Label Review: 03/19/1993 Status Code: C Label Date: 03/19/1993 Origination Code: G Eye Protection IND: YES Skin Protection IND: YES Signal Word: WARNING Respiratory Protection IND: YES Health Hazard: Slight Contact Hazard: Slight Fire Hazard: Moderate Reactivity Hazard: None Hazard And Precautions: COMBUSTIBLE. KEEP AWAY FROM HEAT AND OPEN FLAME. ACUTE: INHALATION CAN CAUSE HEADACHE, DIZZINESS, STAGGERING, CONFUSION, OR COMA. CAN CAUSE PRIMARY EYE AND SKIN IRRITATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.