PHILIPS ECG INC -- HEAVY DUTY FLUX REMOVER - PH600 -- 6850-00N031625 ===================== Product Identification ===================== Product ID:HEAVY DUTY FLUX REMOVER - PH600 MSDS Date:03/07/1986 FSC:6850 NIIN:00N031625 MSDS Number: BNSHS === Responsible Party === Company Name:PHILIPS ECG INC Address:100 FIRST AVE City:WALTHAM State:MA ZIP:02254 Country:US Info Phone Num:617-890-6107 Emergency Phone Num:800-424-9300(CHEMTREC) Preparer's Name:LLOYD FLANNER CAGE:34167 === Contractor Identification === Company Name:PHILIPS ECG Address:3 BALDWIN GREEN UNIT 109 Box:City:WOBURN State:MA ZIP:01801 Country:US Phone:617-932-9070 CAGE:0AD30 Company Name:PHILIPS ECG INC DIV OF NORTH AMERICAN PHILIPS CORP Address:3101 PLEASANT VALLEY RD Box:City:ALTOONA State:PA ZIP:16603 Country:US CAGE:34167 ============= Composition/Information on Ingredients ============= Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) CAS:75-09-2 RTECS #:PA8050000 OSHA PEL:500 PPM, C;1000 PPM ACGIH TLV:50 PPM EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:ISOPROPYL ALCOHOL (SARA III) CAS:67-63-0 RTECS #:NT8050000 OSHA PEL:400 PPM;500 PPM STEL ACGIH TLV:400 PPM;500 PPM STEL Ingred Name:METHANOL; (METHYL ALCOHOL) CAS:67-56-1 RTECS #:PC1400000 OSHA PEL:S,200PPM/250STEL ACGIH TLV:S,200PPM/250STEL; 93 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:TRICHLOROFLUOROMETHANE; (TRICHLOROMONOFLUOROMETHANE) (SARA III) CAS:75-69-4 RTECS #:PB6125000 OSHA PEL:1000 PPM ACGIH TLV:C, 1000 PPM; 9293 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ozone Depleting Chemical:1 Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE; (TRICHLOROTRIFLUOROETHANE) (SARA III) CAS:76-13-1 RTECS #:KJ4000000 OSHA PEL:1000 PPM;1250 STEL ACGIH TLV:1000 PPM;1250 STEL Ozone Depleting Chemical:1 Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 OSHA PEL:5000 PPM ACGIH TLV:5000PPM/30000STEL;93 ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:ACUTE:INHAL:MAY CAUSE DIZZ/NARCOS IN HIGH VAP CONCS. DFCLTY IN BRTHG. SKIN:REDNESS. WILL CAUSE DEFAT OF SKIN. EFTS ARE REVERSIBLE. INGEST:VOMIT. CHRONIC:VAP MAY CAUSE LUNG, LIVER/KIDNEY DMG. CHLOROCAR BON/CHLOROFLUOROCARBON (CFC) MATLS HAVEPRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & (EFTS OF OVEREXP) Explanation of Carcinogenicity:METHYLENE CHLORIDE:ANTICIPATED TO BE A CARCINOGEN(NTP), GROUP 2B(IARC). Effects of Overexposure:HLTH HAZ:COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (I.E., EPINEPHRINE) MAY BE CONTRA-INDICATED EXCEPT FOR LIFE- SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS OR CFC'S ( ). Medical Cond Aggravated by Exposure:HEART DISEASE. ======================= First Aid Measures ======================= First Aid:INHAL:GIVE OXYGEN. INGEST:INDUCE VOMITING. GASTRIC LAVAGE. EYES:WASH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH W/ WATER. ===================== Fire Fighting Measures ===================== Flash Point:NONE Lower Limits:NONE Upper Limits:NONE Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CO2. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT . AEROSOL CANS MAY RUPTURE WHEN HEATED. Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE FLUORIDES, CHLORIDES, HCL & PHOSGENE . ================== Accidental Release Measures ================== Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP MATERIAL. PUT INTO CONTAINER. DISPOSE AS HAZARDOUS WASTE. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, OR OPEN FLAME. STORE AT TEMPERATURES BELOW 120F. Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION MAY CAUSE FORMATION OF CHLORIDES, FLUORIDES, HCL & PHOSGENE . ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPROVED SCBA IF ABOVE TLV LIMIT. Ventilation:LOCAL EXHAUST VENTILATION. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:LONG SLEEVES & LONG PANTS. Work Hygienic Practices:DO NOT SMOKE WHILE SPRAYING; WASH HANDS AFTER USE. Supplemental Safety and Health VP:100 PSIG @ 70F. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:>75F,>24C Melt/Freeze Pt:M.P/F.P Text:N/A LIQUID Vapor Pres:SUPP DATA Vapor Density:4(HVR/AIR) Spec Gravity:1.2 (H2O=1) Evaporation Rate & Reference:6 (BUTYL ACETATE=1) Solubility in Water:NONE Appearance and Odor:CLEAR, ETHEREAL ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE Stability Condition to Avoid:HIGH TEMPERATURES. Hazardous Decomposition Products:IN FIRE PRODUCT MAY DECOMPOSE TO PHOSGENE. CHLORIDES, FLUORIDES & HCL . ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE AS HAZARDOUS WASTE I/A/W EPA RCRA. DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS . Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.