BAYER CORP -- ICTOTEST TABLETS, 2591 ======================================================= MSDS Safety Information ======================================================= FSC: 6550 NIIN: 01-023-7977 MSDS Date: 03/01/1995 MSDS Num: CGVMX Product ID: ICTOTEST TABLETS, 2591 MFN: 01 Responsible Party Cage: JO283 Name: BAYER CORP Address: 511 BENEDICT AVE City: TARRYTOWN NY 10591 Info Phone Number: 800-348-8100 Emergency Phone Number: 219-264-8400;800-424-9300(CHEMTREC) Preparer's Name: T.E. GARLAND Published: Y ======================================================= Contractor Summary ======================================================= Cage: JO283 Name: BAYER CORP Address: 100 BAYER RD Box: 4913 City: PITTSBURGH PA 15205-9741 Phone: 800-662-2927 Cage: 59426 Name: TECHNICON INSTRUMENTS CORP/BAYER CORP DIAGNOSTIC DIV Address: 511 BENEDICT AVE City: TARRYTOWN NY 10591-5005 Phone: 914-353-1427 ======================================================= Item Description Information ======================================================= Item Name: TEST KIT,BILIRUBIN DETERMINATION ======================================================= Ingredients ======================================================= Cas: 5965-83-3 Name: 5-SULFOSALICYLIC ACID; (5-SULFOSALICYLIC ACID, DIHYDRATE). LD50:(ORAL,RAT) 2450 MG/KG. % Wt: 87.2 OSHA PEL: N/K (FP N) ACGIH TLV: N/K (FP N) ------------------------------ Cas: 10043-35-3 RTECS #: ED4550000 Name: BORIC ACID. LD50:(ORAL,RAT) 2660 MG/KG. % Wt: 7.6 OSHA PEL: 10 MG/M3 (BORATES) ACGIH TLV: 5 MG/M3 (BORATES) ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: SEE INGREDIENTS. Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: CRITICAL HAZARDS TO MAN:CORROSIVE, WHEN WET OR DISSOLVED CAN CAUSE BURNS TO EYES AND SKIN. ACUTE:INHALATION:CORROSIVE! INHALATION OF DUSTS OR MISTS MAY CAUSE MUCOUS MEMBRANE AND RESPIRATORY IRRITATION WITH POSSIBLE PERMANENT EDEMA AND POSSIBLE SYSTEMIC EFFECTS SIMILAR TO INGESTION. INGESTION:CORROSIVE!(EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT Signs And Symptions Of Overexposure: HLTH HAZ:SWALLOWING MAY CAUSE GI BURNS & DMG, NAUS, VOMIT, DIARR, LOWERING OF BLOOD PRESS, RASH, HDCH & KIDNEY INJURY. SKIN CONT:CORROSIVE! CONT MAY CAUSE CHEM BURNS & TISS DMG. EYE CONT:CORROSIVE, MA Y CAUSE CHEM BURNS & POSSIBLE BLINDNESS. CHRONIC:PRLNG ABSORPTION OF BORIC ACID MAY CAUSE WT LOSS, SKIN RASH, (SUPDAT) Medical Cond Aggravated By Exposure: NONE CURRENTLY KNOWN. First Aid: CALL MD IMMED & ARRANGE FOR TRANSPORT TO NEAREST ER (EMER ROOM). WHILE AWAITING MD/TRANSPORT TO ER: INHAL:IF NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYG. GET IMMED MED ATTN. INGEST:WASH OU T MOUTH W/WATER PROVIDED PERS IS CONSCIOUS. GIVE 1-2 GLASSES OF MILK/WATER TO DILUTE & INDUCE VOMIT. GET IMMED MED ATTN. SKIN:IMMED REMOVE ANY CONTAM CLTHG. WASH CONT AREA THORO W/WATER FOR AT(SUPDAT) ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: WEAR APPROPRIATE PROTECTIVE EQUIPMENT. TAKE UP SPILLED TABLETS & PLACE IN DISPOSAL CONTAINER. WIPE SPILL AREA W/DAMP PAPER TOWELS & PROPERLY DISPOSE. ECOLOGICAL EFFECTS OF THIS MIXTURE HAVE NOT BEEN D ETERMINED. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: PRIMARY CONTAINER TYPE:PRODUCT CONTAINER IS AMBER GLASS. EACH DISPOSAL FACILITY MUST DETERMINE PROPER DISPOSAL METHODS TO COMPLY W/LOCAL, STATE & FEDERAL ENVIRONMENTAL REGULATIONS. Handling And Storage Precautions: STORE AT TEMPERATURE & CONDITIONS AS INDICATED ON PRODUCT LABELS. KEEP CONTAINERS CLOSED. Other Precautions: CORROSIVE! PREVENT CONTACT W/EYES, SKIN & CLOTHING. KEEP TABLETS DRY, TABLETS ARE SENSITIVE TO MOISTURE FROM AIR OR WATER. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: NONE Extinguishing Media: USE ANY MEDIA THAT IS APPROPRIATE FOR SURROUNDING FIRE. Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N). WET TABLETS ARE CORROSIVE - PREVENT CONTACT. Unusual Fire/Explosion Hazard: NONE DETERMINED. ======================================================= Control Measures ======================================================= Respiratory Protection: NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N). NONE REQUIRED. Ventilation: USE GENERAL ROOM VENTILATION. Protective Gloves: STD LAB CHEMICAL RUBBER/LATEX GLOVES. Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT) Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). Work Hygienic Practices: CONTACT LENSES SHOULD NOT BE WORN IN THE LABORATORY. Supplemental Safety and Health: EFTS OF OVEREXP:CONVLS & LIVER/KIDNEY INJURY. FIRST AID PROC:LST 15 MINS. GET PROMPT MED ATTN. WASH CLTHG BEFORE REUSE. EYES:FLUSH W/COPIOUS AMTS OF WATER FOR AT LST 15-20 MINS. RAISE EYE LIDS SEVERAL TIMES TO BE SURE MATL IS RINSED OUT. TRANSPORT TO HOSPITAL TO SEE OPHTHALMOLOGIST. EYE PROT:& FULL LGTH FSHLD (FP N). ======================================================= Physical/Chemical Properties ======================================================= Solubility in Water: SLOWLY SOLUBLE Appearance and Odor: SOLID WHITE TABLETS. ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: NONE DETERMINED. Materials To Avoid: AVOID ACCIDENTAL CONTACT W/MOISTURE OR WATER. AVOID BASES. Hazardous Decomposition Products: DECOMPOSITION IN WATER WILL PRODUCE AN ACIDIC SOLUTION & HEAT. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= Transportation Information ======================================================= Responsible Party Cage: JO283 Trans ID NO: 99724 Product ID: ICTOTEST TABLETS, 2591 MSDS Prepared Date: 03/01/1995 Review Date: 06/01/1998 MFN: 1 Multiple KIT Number: 0 Review IND: Y ======================================================= Detail DOT Information ======================================================= DOT PSN Code: DXP Symbols: G DOT Proper Shipping Name: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. Hazard Class: 8 UN ID Num: UN3261 DOT Packaging Group: II Label: CORROSIVE Packaging Exception: 154 Non Bulk Pack: 212 Bulk Pack: 240 Max Qty Pass: 15 KG Max Qty Cargo: 50 KG Vessel Stow Req: B ======================================================= Detail IMO Information ======================================================= IMO PSN Code: ETC IMO Proper Shipping Name: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. o IMDG Page Number: 8150-1 UN Number: 3261 UN Hazard Class: 8 IMO Packaging Group: I/II/III Subsidiary Risk Label: - EMS Number: 8-15 MED First Aid Guide NUM: 760 ======================================================= Detail IATA Information ======================================================= IATA PSN Code: HMB IATA UN ID Num: 3261 IATA Proper Shipping Name: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. * IATA UN Class: 8 IATA Label: CORROSIVE UN Packing Group: I Packing Note Passenger: 810 Max Quant Pass: 1KG Max Quant Cargo: 25KG Packaging Note Cargo: 811 Exceptions: A3 ======================================================= Detail AFI Information ======================================================= AFI PSN Code: HMR AFI Symbols: * AFI Proper Shipping Name: CORROSIVE SOLID, ACIDIC, ORGANIC, N.O.S. AFI Hazard Class: 8 AFI UN ID NUM: UN3261 AFI Packing Group: II Special Provisions: P5 Back Pack Reference: A12.4 ======================================================= HAZCOM Label ======================================================= Product ID: ICTOTEST TABLETS, 2591 Cage: JO283 Assigned IND: Y Company Name: BAYER CORP Street: 100 BAYER RD PO Box: 4913 City: PITTSBURGH PA Zipcode: 15205-9741 Health Emergency Phone: 219-264-8400;800-424-9300(CHEMTREC) Label Required IND: Y Date Of Label Review: 04/15/1998 Status Code: C Label Date: 04/15/1998 Origination Code: G Chronic Hazard IND: Y Eye Protection IND: YES Skin Protection IND: YES Signal Word: DANGER Respiratory Protection IND: YES Health Hazard: Severe Contact Hazard: Severe Fire Hazard: None Reactivity Hazard: None Hazard And Precautions: CRITICAL HAZS TO MAN:CORROSIVE, WHEN WET/DISSOLVED CAN CAUSE BURNS TO EYES & SKIN. ACUTE:INHAL:CORROSIVE! INHAL OF DUSTS OR MISTS MAY CAUSE MUCOUS MEMBRANE AND RESPIRATORY IRRITATION WITH POSSIBLE PER MANENT EDEMA AND POSSIBLE SYSTEMIC EFFECTS SIMILAR TO INGESTION. INGESTION:CORROSIVE! SWALLOWING MAY CAUSE GI BURNS & DAMAGE, NAUSEA, VOMITING, DIARRHEA, LOWERING OF BLOOD PRESSURE, RASH, HEADACHE & K IDNEY INJURY. SKIN CONT:CORROSIVE. MAY CAUSE CHEMICAL BURNS & TISSUE DAMAGE. EYE CONT:CORROSIVE. MAY CAUSE CHEMICAL BURNS & POSSIBLE BLINDNESS. CHRONIC:PROLONGED ABSORPTION OF BORIC ACID MAY CAUSE WT LOSS, SKIN RASH, CONVLS & LIVER/KIDNEY INJURY. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.