PENRECO -- IRM 903 ======================================================= MSDS Safety Information ======================================================= FSC: 9150 MSDS Date: 12/17/1993 MSDS Num: CJYCY LIIN: 00N093458 Product ID: IRM 903 MFN: 01 Responsible Party Cage: HO424 Name: PENRECO Address: 4426 EAST WASHINGTON BOULEVARD City: LOS ANGELES CA 99023-4411 Info Phone Number: 800-546-6227 Emergency Phone Number: 800-546-6040 Resp. Party Other MSDS No.: 010593 Preparer's Name: ENVIRON, SAFETY & HEALTH Review Ind: Y Published: Y ======================================================= Contractor Summary ======================================================= Cage: HO424 Name: PENRECO Address: 4426 EAST WASHINGTON BOULEVARD City: LOS ANGELES CA 99023-4411 Phone: 800-546-6227 ======================================================= Item Description Information ======================================================= ======================================================= Ingredients ======================================================= Cas: 64742-52-5 RTECS #: PY8035000 Name: DISTILLATES (PETROLEUM), HYDROTREATED HEAVY NAPHTHENIC; (HEAVY NAPHTHENIC HYDROTREATED DISTILLATE) Percent by Wt: 100. Other REC Limits: N/K (FP N) OSHA PEL: N/K (FP N) OSHA STEL: N/K (FP N) ACGIH TLV: N/K (FP N) ACGIH STEL: N/K (FP N) ======================================================= Health Hazards Data ======================================================= Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: EYES: PRACTICALLY NON-IRRITATING TO EYES UPON DIRECT CONT, BASED ON TESTING OF SIMILAR PRODS &/OR COMPONENTS. SKIN: AVOID CONT. MAY CAUSE SLIGHT IRRIT UPON DIRECT CONT, BASED ON TESTING OF SIMILAR PRO DS &/OR COMPONENTS. PRLNG/RPTD CONT MAY RSLT IN CONT DERM WHICH IS CHARACTERIZED BY DRYNESS, CHAPPING, & REDDENING. THIS CNDTN MAY MAKE SKIN MORE SUSCEPTIBLE TO OTHER IRRITANTS, SENSITIZERS, & DISEASE . PRLNG/RPTD CONT MAY RSLT IN OIL ACNE WHICH IS CHARACTERIZED BY BLACKHEADS W/POSS SECONDARY INFECTION. SEE HLTH DATA SECTION BELOW. INHAL: PROD HAS LOW VAP PRESS & IS NOT EXPECTED TO PRESENT INHAL HA Z AT AMBIENT CNDTNS. (EFTS OF OVEREXP) Explanation Of Carcinogenicity: IARC HAS CONCLUDED THAT HIGHLY REFINED MINERAL OILS ARE GROUP 3 SUBSTANCES, "NOT CLASSIFIABLE AS TO THEIR CARCINOGENICITY TO HUMANS", BASED ON INADEQUATE HUMAN AND INADEQUATE ANIMAL EVIDENCE. THIS SUB STANCE IS NOT CARCINOGENIC ACCORDING TO THE OSHA HAZARD COMMUNICATION STANDARD. Signs And Symptions Of Overexposure: HLTH HAZ: CAUTION SHOULD BE TAKEN TO PVNT AEROSOLIZATION/MISTING OF PROD. PEL & TLV FOR PROD AS OIL MIST IS 5 MG/M3. EXPOS BELOW 5 MG/M3 APPEAR TO BE W/OUT SIGNIFICANT HLTH RISK. SHORT-TERM EXPOS LIM FOR PROD AS OIL MIST IS 10 MG/M3. INGEST: DO NOT INGEST. PROD IS RELATIVELY NON-TOX BY INGEST. PROD HAS LAXATIVE PROPERTIES & MAY RSLT IN ABDOM CRAMPS & DIARR. SEE HLTH DATA SECTION BELOW. HLTH DATA: ON RARE OCCASIONS, PRLNG & RPTD EXPOS TO OIL MIST POSES RISK OF PULM DISEASE SUCH AS CHRONIC LUNG INFLAMM. THIS CNDTN IS USUALLY ASYMPTOMATIC AS A RESULT OF RPTD SML ASPIRATIONS. SHORTNESS OF BREATH & COUGH ARE MOST COMMON SYMPS. First Aid: EYES: IMMED FLUSH W/LARGE AMOUNTS OF WATER & CONTINUE FLUSHING UNTIL IRRIT SUBSIDES (AT LEAST 15 MINUTES). IF MATERIAL IS HOT, TREAT FOR THERMAL BURNS & TAKE TO HOSPITAL IMMED. SKIN: REMOVE CONTAMINAT ED CLOTHING. WASH CONTAMINATED AREA THORO W/SOAP & WATER. IF REDNESS/IRRIT OCCURS, SEEK MED ATTN. IF MATERIAL IS HOT, SUBMERGE INJURED AREA IN COLD WATER. IF SEVERELY BURNED, REMOVE TO HOSPITAL IMMED. INHAL: THIS MATERIAL HAS LOW VAPOR PRESSURE & IS NOT EXPECTED TO PRESENT INHAL EXPOS AT AMBIENT CONDITIONS. REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) (FP N). INGEST: DO NOT INDUCE VOMITING. SEEK MED ATTN. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: CONSULT HLTH EFTS INFO, PERS HLTH PROT INFO, FIRE PROT INFO, & REACTIVITY DATA. NOTIFY APPROP AUTHS OF SPILL. CONTAIN SPILL IMMED. DO NOT ALLOW SPILL TO ENTER SEWERS/WATERCOURSES. REMOVE ALL SOURCES O F IGNIT. ABSORB W/APPROP INERT MATL SUCH AS SAND, CLAY, ETC. LGE SPILLS MAY BE PICKED UP USING VACUUM PUMPS, SHOVELS, BUCKETS/OTHER MEANS & PLACED IN DRUMS/OTHER SUITABLE CONTRS. Waste Disposal Methods: ALL DISPS MUST COMPLY W/FED, STATE, & LOC REGS. MATL, IF SPILLED/DISCARDED, MAY BE REGULATED WASTE. REFER TO STATE & LOC REGS. CAUTION! IF REGULATED SOLVS ARE USED TO CLEAN UP SPILLED MATL, RESULTING WASTE MIXT MAY BE REGULATED. DOT REGS MAY APPLY FOR TRANSPORTING MATL WHEN SPILLED. (SUP DAT) Handling And Storage Precautions: DO NOT TRANSFER TO UNMARKED CONTAINERS. STORE IN CLOSED CONTAINERS AWAY FROM HEAT, SPARKS, OPEN FLAME/OXIDIZING MATERIALS. PRODUCT IS NOT CLASSIFIED AS HAZARDOUS UNDER DOT REGULATIONS. FIRE EXTINGUISH ERS SHOULD BE KEPT READILY AVAILABLE. SEE NFPA 30 & OSHA 1910.106--FLAMMABLE & COMBUSTIBLE LIQUIDS. Other Precautions: MIXTURE MAY BE FORMULATED IN PART W/COMPONENTS PURCHASED FROM OTHER COMPANIES. IN MANY INSTANCES, ESPECIALLY WHEN PROPRIETARY/TRADE SECRET MATERIALS ARE USED, PENNZOIL COMPANY MUST RELY UPON HAZARD EV ALUATION OF SUCH COMPONENTS SUBMITTED TO PENNZOIL BY THAT PRODUCT'S MFR/IMPORTER. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Method: PMCC Flash Point: >150.C, 302.F Extinguishing Media: USE DRY CHEMICAL, FOAM, OR CARBON DIOXIDE. Fire Fighting Procedures: WEAR NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE EQUIPMENT (FP N). WATER MAY BE INEFFECTIVE BUT CAN BE USED TO COOL CONTAINERS EXPOSED TO HEAT OR FLAME. CAUTION SHOULD BE EXE RCISED WHEN USING WATER OR FOAM AS FROTHING MAY OCCUR, ESPECIALLY IF SPRAYED INTO CONTAINERS OF HOT, BURNING LIQUID. Unusual Fire/Explosion Hazard: DENSE SMOKE MAY BE GENERATED WHILE BURNING. CARBON MONOXIDE, CARBON DIOXIDE, AND OTHER OXIDES MAY BE GENERATED AS PRODUCTS OF COMBUSTION. ======================================================= Control Measures ======================================================= Respiratory Protection: RESPIRATORY PROTECTION IS NOT REQUIRED UNDER CONDITIONS OF NORMAL USE. IF VAPOR OR MIST IS GENERATED WHEN THE MATERIAL IS HEATED OR HANDLED, USE AN ORGANIC VAPOR RESPIRATOR WITH A DUST AND MIST FILTER . ALL RESPIRATORS MUST BE NIOSH CERTIFIED. DO NOT USE COMPRESSED OXYGEN IN HYDROCARBON ATMOSPHERES. Ventilation: IF VAP/MIST IS GENERATED WHEN MATL IS HEATED/HANDLED, ADEQ VENT I/A/W GOOD ENGINEERING PRACTICE MUST BE PROVIDED TO MAINTAIN CONCS BELOW (SUP DAT) Protective Gloves: IMPERVIOUS GLOVES FOR PROLONGED OR REPEATED EXPOSURES. Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N). Other Protective Equipment: EYEWASH & DELUGE SHWR MTG ANSI DESIGN CRITERIA(FP N). NO SKIN PROT IS REQ FOR SINGLE, SHORT DURATION EXPOS. FOR PRLNG/RPTD EXPOS, USE IMPERVIOUS (BOOTS, APRONS, ETC) OVER PARTS OF BODY SUBJECT (SUP DAT) Work Hygienic Practices: CONSUMPTION OF FOOD & BEVERAGE SHOULD BE AVOIDED IN WORK AREAS WHERE HYDROCARBONS ARE PRESENT. ALWAYS WASH HANDS & FACE W/SOAP & WATER BEFORE EATING, DRINKING/SMOKING. (OTHER INFO) Supplemental Safety and Health: WASTE DISPOSAL METHOD: WASTE MATERIAL MAY BE LANDFILLED/INCINERATED AT APPROVED FACILITY. MATERIALS SHOULD BE RECYCLED IF POSS. -- VENT: SPECIFIC EXPOSURE/FLAMMABLE LIMITS. -- OTHER PROT EQUIP: TO EXP OSURE. IF HANDLING HOT MATERIAL, USE INSULATED PROTECTIVE CLOTHING (BOOTS, GLOVES, APRONS, ETC). ======================================================= Physical/Chemical Properties ======================================================= Boiling Point: >260.C, 500.F Vapor Pres: NEGLIGIBLE Spec Gravity: 0.9 Solubility in Water: INSOLUBLE Appearance and Odor: CLEAR STRAW TO YELLOW LIQUID; NO DATA FOR ODOR. ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: NONE. Materials To Avoid: MAY REACT WITH STRONG OXIDIZING AGENTS. Hazardous Decomposition Products: NONE. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NONE. ======================================================= Regulatory Information ======================================================= Sara Title III Information: THIS PRODUCT IS NOT KNOWN TO CONTAIN ANY SARA TITLE III, SECTION 313 REPORTABLE CHEMICALS AT OR GREATER THAN 1.0% (0.1% FOR CARCINOGENS). ======================================================= Other Information ======================================================= Other Information: NFPA HAZARD IDENTIFICATION: DEGREE OF HAZARD: HEALTH = 0; FIRE = 1; REACTIVITY = 0; HAZARD RATINGS: 0-LEAST, 1-SLIGHT, 2-MODERATE, 3-HIGH, 4-EXTREME. -- HYGIENE PRACTICES: PROPERLY DISPOSE OF CONTAMIN ATED LEATHER ARTICLES INCLUDING SHOES, WHICH CANNOT BE DECONTAMINATED. ======================================================= HAZCOM Label ======================================================= Product ID: IRM 903 Cage: HO424 Assigned IND: Y Company Name: PENRECO Street: 4426 EAST WASHINGTON BOULEVARD City: LOS ANGELES CA Zipcode: 99023-4411 Health Emergency Phone: 800-546-6040 Label Required IND: Y Date Of Label Review: 12/29/1999 Status Code: A Origination Code: F Eye Protection IND: YES Skin Protection IND: YES Signal Word: CAUTION Respiratory Protection IND: YES Health Hazard: Slight Contact Hazard: Slight Fire Hazard: Slight Reactivity Hazard: None Hazard And Precautions: ACUTE: EYES: PRACTICALLY NON-IRRITATING. SKIN: MAY CAUSE SLIGHT IRRIT UPON DIRECT CONT. PRLNG/RPTD CONT MAY RSLT IN CONT DERM WHICH IS CHARACTERIZED BY DRYNESS, CHAPPING, & REDDENING. THIS CNDTN MAY M AKE SKIN MORE SUSCEPTIBLE TO OTHER IRRITANTS, SENSITIZERS, & DISEASE. PRLNG/RPTD CONT MAY RSLT IN OIL ACNE WHICH IS CHARACTERIZED BY BLACKHEADS W/POSS SECONDARY INFECTION. INHAL: PROD HAS LOW VAP PRE SS & IS NOT EXPECTED TO PRESENT INHAL HAZ AT AMBIENT CNDTNS. CHRONIC: NONE LISTED BY MANUFACTURER. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.