CALGON VESTAL LABORATORIES INC -- MEDICATED LOTION SOAP, 6262 ======================================================= MSDS Safety Information ======================================================= FSC: 6508 MSDS Date: 07/21/1993 MSDS Num: BXTSY LIIN: 00N059953 Product ID: MEDICATED LOTION SOAP, 6262 MFN: 01 Responsible Party Cage: 21667 Name: CALGON VESTAL LABORATORIES INC Address: 5035 MANCHESTER AVE City: ST LOUIS MO 63110 Info Phone Number: 314-535-1810 Emergency Phone Number: 800-424-9300(CHEMTREC) Preparer's Name: A. SCHMITT Published: Y ======================================================= Contractor Summary ======================================================= Cage: 21667 Name: CONVATEC, BRISTOL-MEYERS SQUIBB CO Address: 7501 PAGE Box: 147 City: ST. LOUIS MO 63166-1096 Phone: 314-535-1810 (DAY) ======================================================= Ingredients ======================================================= Name: NON-HAZARDOUS INGREDIENTS OSHA PEL: N/K (FP N) ACGIH TLV: N/K (FP N) ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: LD50(ORAL,RAT):>5 ML/KG Route Of Entry Inds - Inhalation: NO Skin: YES Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: ACUTE:EYES:THIS PRODUCT WILL CAUSE IRRITATION UPON DIRECT EYE CONTACT. SKIN:PROLONGED EXPOSURE TO PRODUCT WITHOUT RINSE MAY PRODUCE IRRITATION. INGESTION:OVEREXPOSURE TO PRODUCT MAY PRODUCE CRAMPS AND DIARRHEA. CHRONIC:NO AVAILABLE INFORMATION WAS FOUND. Explanation Of Carcinogenicity: NOT RELEVANT Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS. Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER. First Aid: INHALATION:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) (FP N). EYES:FLUSH WITH FLOWING WATER FOR AT LEAST 15 MINUTES. IF IRRITATION PERSISTS, CONTACT A PHYSICIAN. SKIN:WASH OFF WITH WA TER. INGESTION:DRINK PLENTY OF WATER AND CONTACT A PHYSICIAN. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: SPILLS MAY BE PICKED UP WITH A MOP OR WITH FLOWING WATER. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). WASTE SOLUTIONS MAY BE SEWERED. Handling And Storage Precautions: IF FROZEN, THAW AND REMIX BEFORE USE. Other Precautions: READ AND OBSERVE ALL LABELED USE INSTRUCTIONS. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: NONE Extinguishing Media: SUITABLE TO ORIGIN OF FIRE-WATER, CO*2, FOAM, DRY CHEMICAL. Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N). ======================================================= Control Measures ======================================================= Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N). NOT APPLICABLE Ventilation: NORMAL ROOM VENTILATION. Protective Gloves: HAND SOAP. NOT APPLICABLE. Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N). Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER. ======================================================= Physical/Chemical Properties ======================================================= M.P/F.P Text: 28.0F,-2.2C Spec Gravity: 1.03 (H*2O=1) PH: 9.0 Solubility in Water: 99.5% Appearance and Odor: WHITE OPAQUE CREAM, PLEASANT FRAGRANCE Percent Volatiles by Volume: 77(WT) ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: NONE KNOWN. Materials To Avoid: NONE KNOWN. Hazardous Decomposition Products: FORCED IGNITION OF DRIED RESIDUES MAY PRODUCE CO, CO*2, NITROGEN OXIDES. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= HAZCOM Label ======================================================= Product ID: MEDICATED LOTION SOAP, 6262 Cage: 21667 Company Name: CONVATEC, BRISTOL-MEYERS SQUIBB CO Street: 7501 PAGE PO Box: 147 City: ST. LOUIS MO Zipcode: 63166-1096 Health Emergency Phone: 800-424-9300(CHEMTREC) Label Required IND: Y Date Of Label Review: 05/19/1995 Status Code: C Label Date: 05/19/1995 Origination Code: G Eye Protection IND: YES Skin Protection IND: YES Signal Word: CAUTION Respiratory Protection IND: YES Health Hazard: Slight Contact Hazard: Slight Fire Hazard: None Reactivity Hazard: None Hazard And Precautions: ACUTE:EYES:THIS PRODUCT WILL CAUSE IRRITATION UPON DIRECT EYE CONTACT. SKIN:PROLONGED EXPOSURE TO PRODUCT WITHOUT RINSE MAY PRODUCE IRRITATION. INGESTION:OVEREXPOSURE TO PRODUCT MAY PRODUCE CRAMPS AND DIARRHEA. CHRONIC:NONE LISTED BY MANUFACTURER. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.