AMBION, INC.     MEGAclear™­96 Kit      Catalog #: 1909    Binding Solution      Material Safety Data Sheet  Version: 1  Created: 022805  Page 1 of 3  Printed: 4/26/2005  Revision Date: N.A  QC Form: 2201       Section 1­Identification of Product  8540G9  WHMIS Classification  Product Use    Health:   2   Fire:   0   Stability:   0  Contact Information  Ambion, Inc 2130 Woodward St. Austin, TX 78744­1832 Tel: +1 512 651 0200 US Toll­free Tel: 800 888 8804 E­ mail: techserv@ambion.com Web address www.ambion.com     Ambion (Europe) LTD Huntingdon, Cambidgeshire UK PE29 6XY Tel:+44 (0)1480 373 020 Fax: +44 (0)1480 373  010 E­mail: eurotech@ambion.com Web address: www.ambion.com     Emergency Contact: In Europe, call 112.  In USA, call 911  Section 2­Composition/Information  Hazardous Ingredients (Specific)  %  CAS #  LD50 LC 50  Trade secret  20­70  Trade secret  Intraperitoneal­ Mouse LD50:  300 mg/kg  Not Tested  Section 3­Hazard Identification  Routes of Entry    Skin Contact  Causes skin irritation.  May cause skin sensitization, an allergic  reaction, which becomes evident upon re­exposure to this material.    Skin Absorption  In the presence of moisture this material may be absorbed through the  skin.  May cause symptoms similar to indigestion.  Eye Contact  Causes eye irritation.  May cause conjunctivitis, ulceration and  turbidity of the cornea.  Inhalation  May cause similar effects as indigestion.  Exposure causes central  nervous system depression.  Causes irritation of the mucous  membranes.  High concentrations of thiocyanates can lead to fatal  pulmonary edema.    Ingestion  May cause irritation to the digestive tract.  May cause liver and kidney  damage.  Ingestion of thiocyanates may cause disorientation,  weakness, low blood pressure, confusion, psychotic behavior,  muscular spasms, convulsions and death.  [Emergency Overview]    WARNING! HARMFUL IF SWALLOWED OR INHALED. CAUSES IRRITATION TO SKIN  WHMIS Symbols    N.A  [Potential Health Effects]    May cause liver and kidney damage.  Effects may be delayed.  May cause lung damage.  Repeated or prolonged  exposure may result in allergic reactions in some people.  Inhalation of product may aggravate existing chronic  respiratory problems such as asthma, emphysema or bronchitis.  Section 4­First Aid Measures  Skin Contact  Get medical aid.  Immediately flush skin with plenty of soap and water for at least 15 minutes  while removing contaminated clothing and shoes.  Wash clothing before reuse.  Destroy  contaminated shoes.  Eye Contact  Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the  upper and lower eyelids.  Get medical aid immediately.  Do not allow victim to rub or keep eyes  closed.  Inhalation  Remove from exposure to fresh air immediately.  If not breathing, give artificial respiration.  If  breathing is difficult, give oxygen.  Get medical aid.  Do not use mouth­to­mouth resuscitation.  Ingestion  Do not induce vomiting.  If victim is conscious and alert, give 2­4 cupfuls of milk or water.   Never give anything by mouth to an unconscious person.  Get medical aid immediately.    Section 5­Fire Fighting Measures  Flammable Nonflammable  Means of Extinction  Use water spray, dry chemical, carbon dioxide, or  appropriate foam.  Flashpoint (oC) and Method  Not Tested  Upper Flammable Limit (% by volume)  Not Tested  = Page 1 = AMBION, INC.     MEGAclear™­96 Kit      Catalog #: 1909    Binding Solution      Material Safety Data Sheet  Version: 1  Created: 022805  Page 2 of 3  Printed: 4/26/2005  Revision Date: N.A  QC Form: 2201       Lower Flammable Limit (% by volume)  Not Tested  Autoignition Temperature (oC) Not Tested  Explosion Data – Sensitivity to Impact  Not Tested  Explosion Data – Sensitivity to Static Discharge  Not Tested  Hazardous Combustion Products  Irritating and highly toxic gases may be generated by  thermal decomposition or combustion.  NFPA Not Tested  Section 6­Accidental Release Measures  Leak and Spill Procedures    Wash area with soap and water.  Clean up spills immediately, observing precautions in the protective equipment  section.  Sweep up, then place into a suitable container for disposal.  Avoid generating dusty conditions.  Provide  ventilation.  Section 7­Handling and Storage  Handling Procedures and  Equipment  Wash thoroughly after handling.  Use with adequate3 ventilation.  Minimize dust  generation and accumulation.  Avoid contact with eyes, skin, and clothing.   Avoid ingestion and inhalation.  Store protected from light.  Discard  contaminated shoes.  Storage Requirements  Do not store in direct sunlight.  Keep container closed when not in use.  Store in  a cool, dry, well­ventilated area away from incompatible substances.  Store  protected from light.  Section 8­Exposure Control/Personal Protection  Exposure Limits  ACGIH TLV  Not Listed  OSHA PEL  Not Listed  Other (specify)  N.A.  Engineering Controls (specific)  General  Facilities storing or utilizing this material should be equipped with an eyewash  facility and a safety shower. Use adequate ventilation to keep airborne  concentrations low.  Local Exhaust  A system of local and/or general exhaust is recommended to keep employee  exposures as low as possible. Local exhaust ventilation is generally preferred  because it can control the emissions of the contaminant at its source, preventing  dispersion of it into the general work area. Please refer to the ACGIH document,  Industrial Ventilation, A Manual of Recommended Practices, most recent  edition, for details.  Other N.A.  Personal Protective Equipment (specific)  Gloves Synthetic gloves  Respirator  A respiratory protection program that meets OSHA's 29 CFR 1910.134 and  ANSI Z88.2 requirements or European Standard EN 149 must be followed  whenever workplace conditions warrant a respirator's use.  Eye  Wear appropriate protective eyeglasses or chemical safety goggles as described  by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European  Standard EN166. Maintain eye wash fountain and quick­drench facilities in work  area.  Footwear  Closed toe shoes  Clothing  Wear appropriate protective clothing to prevent skin exposure.  Other   N.A.  Section 9­Physical and Chemical Properties  Physical State  Liquid  Odor and Appearance  None/White  Odor Threshold (ppm)  Not Tested  Specific Gravity  Not Tested  Vapor Density (Air=1)  Not Tested  Vapor Pressure (mmHg)  Not Tested  Evaporation Rate  Not Tested  Boiling Point (oC) Not Tested  Freezing Point (oC) Not Tested  = Page 2 = AMBION, INC.     MEGAclear™­96 Kit      Catalog #: 1909    Binding Solution      Material Safety Data Sheet  Version: 1  Created: 022805  Page 3 of 3  Printed: 4/26/2005  Revision Date: N.A  QC Form: 2201       pH Not Tested  Coefficient of Water/Oil Distribution  Not Tested  [Solubility in Water]  Not Tested  Section 10­Stability and Reactivity  Chemical Stability  Stable under normal temperatures and pressures.  Incompatible with other substances  Strong bases, strong oxidizing agents, water, and acids.  Reactivity NA  Hazardous Decomposition Products  Hydrogen cyanide, nitrogen oxides, carbon monoxide, oxides of  nitrogen, oxides of sulfur, carbon dioxide, cyanide fumes,  hydrocarbons.  Section 11­Toxicological Information  Acute Effects  Not Listed  Chronic Effects  May cause liver and kidney damage.  Effects may be delayed.  May cause lung  damage.  Repeated or prolonged exposure may result in allergic reactions in  some people.  Inhalation of product may aggravate existing chronic respiratory  problems such as asthma, emphysema or bronchitis.  Irritancy of Product  Eyes, skin, respiratory, gastrointestinal  Skin Sensitization  Yes  Respiratory Sensitization  Not Listed  Carcinogenicity  IARC (1,2A, or 2B)  Not Listed  ACGIH (A1, A2, or A3)  Not Listed  Reproductive Toxicity  Not Listed  Teratogenicity Not Listed  Embryotoxicity Not Listed  Mutagenicity Not Listed  Name of Synergistic  Products/Effects  Not Listed  Section 12­Ecological Information  Aquatic Toxicity  Not Tested  Section 13­Disposal Considerations  Waste Disposal  Chemical waste generators must determine whether a discarded chemical is  classified as a hazardous waste. US EPA guidelines for the classification  determination are listed in 40 CFR Parts 261.3. Additionally, waste generators  must consult state and local hazardous waste regulations to ensure complete and  accurate classification.  Section 14­Transport Information  Special Shipping Information  PIN Not Listed  TDG Not Listed  [DOT] Not Listed  [IMO] Not Listed  [ICAO] Not Listed  Section 15­Regulatory Information  [WHMIS Classification]  Not Listed  [OSHA] Not Listed  [SERA] Not Listed  [TSCA]  CAS # Trade secret: is listed on the TSCA Inventory.  Section 16­Other Information  This bulletin is for your guidance and is based upon information and tests believed to be reliable.  Ambion makes no  guarantee of the accuracy or completeness of the data and shall not be liable for any damages thereto.  The data are  offered solely for your consideration, investigation, and verification.  These suggestions should not be confused with  state, municipal, or insurance requirements, or with national safety codes and constitute no warranty.  Any use of  these data and information must be determined by the user to be in accordance with applicable federal, state, and local  regulations.    = Page 3 =   Version 1  Revision Date: N.A.  Page 1 of 1  Printed:4/26/2005  Created Date:022805  QC Form 2202  SAFETY STATEMENT  This document is only available in English.        1.  Identification of the substance/preparation and company/undertaking    Product/Kit Name: MEGAclear™­96 Kit    Catalog #: 1909    Product/Component Name: Wash Solution Concentrate  Catalog Number: 9913G9  Supplier: Ambion, Inc.  Emergency Telephone Numbers:   USA: 1­800­888­8804  Europe: +44 (0) 1480 373 020  2.  Composition/ information on ingredients    Substance/Preparation:    To the present knowledge of Ambion, Inc., this product does not contain any hazardous  ingredients in quantities requiring reporting  in this section, in accordance with EU  regulations or National regulations.    To Ambion’s knowledge this substance/preparation is not classified as hazardous  according to EU, US, or any other known national regulations.    9.    Physical and chemical properties     Physical State: Liquid   Color: Colorless    16.   Other information:     To the best of Ambion’s knowledge, the in formation contained herein is accurate.  However, Ambion, Inc. does not  assume any liability whatso ever for the accuracy or  completeness of the information contained herein.  Final determination of suitability of any material  is the sole responsibility of the user. All  materials may present unknown hazards and should be used with caution.    This is not an MSDS. According to EU and US regulations we are not required to supply  an MSDS for a product, which is not classified as hazardous.  = Page 4 =   Version 1  Revision Date: N.A.  Page 1 of 1  Printed:4/26/2005  Created Date:022805  QC Form 2203  SAFETY STATEMENT  This document is only available in English.        1.  Identification of the substance/preparation and company/undertaking    Product/Kit Name: MEGAclear™­96 Kit    Catalog #: 1909    Product/Component Name: Elution Solution  Catalog Number: 9911G3  Supplier: Ambion, Inc.  Emergency Telephone Numbers:   USA: 1­800­888­8804  Europe: +44 (0) 1480 373 020  2.  Composition/ information on ingredients    Substance/Preparation:    To the present knowledge of Ambion, Inc., this product does not contain any hazardous  ingredients in quantities requiring reporting  in this section, in accordance with EU  regulations or National regulations.    To Ambion’s knowledge this substance/preparation is not classified as hazardous  according to EU, US, or any other known national regulations.    9.    Physical and chemical properties     Physical State: Liquid   Color: Colorless    16.   Other information:     To the best of Ambion’s knowledge, the in formation contained herein is accurate.  However, Ambion, Inc. does not  assume any liability whatso ever for the accuracy or  completeness of the information contained herein.  Final determination of suitability of any material  is the sole responsibility of the user. All  materials may present unknown hazards and should be used with caution.    This is not an MSDS. According to EU and US regulations we are not required to supply  an MSDS for a product, which is not classified as hazardous.  = Page 5 =   Version 1  Revision Date: N.A.  Page 1 of 1  Printed:4/26/2005  Created Date:022805  QC Form 2204  SAFETY STATEMENT  This document is only available in English.        1.  Identification of the substance/preparation and company/undertaking    Product/Kit Name: MEGAclear™­96 Kit    Catalog #: 1909    Product/Component Name: Nuclease­free Water  Catalog Number: 9914G6  Supplier: Ambion, Inc.  Emergency Telephone Numbers:   USA: 1­800­888­8804  Europe: +44 (0) 1480 373 020  2.  Composition/ information on ingredients    Substance/Preparation:    To the present knowledge of Ambion, Inc., this product does not contain any hazardous  ingredients in quantities requiring reporting  in this section, in accordance with EU  regulations or National regulations.    To Ambion’s knowledge this substance/preparation is not classified as hazardous  according to EU, US, or any other known national regulations.    9.    Physical and chemical properties     Physical State: Liquid   Color: Colorless    16.   Other information:     To the best of Ambion’s knowledge, the in formation contained herein is accurate.  However, Ambion, Inc. does not  assume any liability whatso ever for the accuracy or  completeness of the information contained herein.  Final determination of suitability of any material  is the sole responsibility of the user. All  materials may present unknown hazards and should be used with caution.    This is not an MSDS. According to EU and US regulations we are not required to supply  an MSDS for a product, which is not classified as hazardous.  = Page 6 =