WESCOR INC -- AEROSPRAY GRAM REAGENT B, IODINE ======================================================= MSDS Safety Information ======================================================= FSC: 6550 NIIN: 01-356-0233 MSDS Date: 07/14/1994 MSDS Num: CLDKV Product ID: AEROSPRAY GRAM REAGENT B, IODINE MFN: 01 Responsible Party Cage: 57699 Name: WESCOR INC Address: 459 S MAIN ST City: LOGAN UT 84321-5207 Info Phone Number: 801-752-6011/800-453-2725 Emergency Phone Number: 800-453-2725 Resp. Party Other MSDS No.: 3718XA Proprietary Ind: Y Review Ind: Y Published: Y ======================================================= Contractor Summary ======================================================= Cage: 57699 Name: WESCOR INC Address: 459 S MAIN ST City: LOGAN UT 84321-5207 Phone: 801-752-6011/800-453-2725 ======================================================= Item Description Information ======================================================= Item Manager: S9M Item Name: GRAM'S IODINE SOLUTION Unit of Issue: BT Quantitative Expression: 00000000500ML UI Container Qty: 500.000 ML ======================================================= Ingredients ======================================================= Name: *** PROPRIETARY *** ----------------------------- ======================================================= Health Hazards Data ======================================================= Skin: YES Ingestion: YES Signs And Symptions Of Overexposure: THE CHEMICAL, PHYSICAL, AND TOXICOLOGICAL PROPERTIES OF THIS SOLUTION HAVE NOT BEEN FULLY ESTABLISHED. SKIN EXPOSURE MAY CAUSE IRRITATION OR BURNS. CHRONIC EXPOSURE MAY CAUSE SKIN RASHES, RHINITIS, AS THMA. LARGE QUANTITIES MAY BE FATAL IF SWALLOWED. First Aid: IN CASE OF EYE CONTACT: IMMEDIATELY WASH EYES WITH COPIOUS AMOUNTS OF WATER FOR 15 MINUTES, SEPARATING EYELIDS WITH FINGERS TO ENSURE ADEQUATE FLUSHING. GET MEDICAL ATTENTION. IN CASE OF SKIN CONTAC T: WASH SKIN THOROUGHLY WITH SOAP AND WATER. WASH ANY CONTAMINATED CLOTHING BEFORE REUSE. IN CASE OF INGESTION: GIVE TWO GLASSES OF WATER AND INDUCE VOMITING (PROVIDED PERSON IS CONSCIOUS). CONTACT A PHYSICIAN OR POISON CONTROL CENTER. IN CASE OF OVEREXPOSURE TO VAPOR: REMOVE PERSON TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. IF SYMPTOMS PER SIST, CALL A PHYSICIAN. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: WEAR GLOVES AND USE ABSORBENT TOWELS TO COLLECT SPILLED LIQUID FOR DISPOSAL. WASH SPILL SITE WITH SOAP AND WATER. USE BIOLOGICAL STAIN REMOVER TO CLEAN STAINED AREAS. Waste Disposal Methods: IF LOCAL REGULATIONS PERMIT, SMALL QUANTITIES MAY BE FLUSHED TO SEWER WITH HEAVY WATER RINSE. OTHERWISE COLLECT MATERIALS USED FOR SPILL CLEANUP FOR INCINERATION OR DISPOSAL IN ACCORDANCE WITH FEDERAL , STATE AND LOCAL REGULATIONS. Handling And Storage Precautions: STORAGE TEMPERATURE MINIMUM 18 C, MAXIMUM 31 C. AVERAGE SHELF LIFE 6 MONTHS. AVOID HEAT, DIRECT SUNLIGHT, FREEZING. KEEP TIGHTLY CAPPED WHEN NOT IN USE. STORE IN DARK AT ROOM TEMPERATURE. KEEP OUT OF THE REACH OF CHILDREN. DO NOT FREEZE. AVOID CONTACT WITH SKIN AND EYES. DO NOT BREATH VAPOR. Other Precautions: *PVP IS AN IARC UNCLASSIFIABLE SUBSTANCE; NO HUMAN DATA AVAILABLE. THE SOLUTION IS COMPOSED PRIMARILY OF DEIONIZED WATER. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: NON-FLAMMABLE Extinguishing Media: ANY APPROPRIATE FOR SURROUNDING CONDITIONS. Fire Fighting Procedures: SELF-CONTAINED BREATHING APPARATUS RECOMMENDED IF FIGHTING FIRES IN THE AREA. ======================================================= Control Measures ======================================================= Respiratory Protection: NONE NORMALLY REQUIRED. Ventilation: MECHANICAL (GENERAL ROOM VENT). Protective Gloves: PLASTIC. Eye Protection: CHEMICAL SPLASH GOGGLES. Other Protective Equipment: EYE WASH FACILITY. Supplemental Safety and Health: PRODUCT NAME: AEROSPRAY GRAM REAGENT B, IODINE. CHEMICAL FAMILY: HALOGENS. CHEMICAL NAME & SYNONYMS: AQUEOUS GRAM IODINE STAIN. TRADE NAME & SYNONYMS: WESCOR GRAM REAGENT B, SS-042B. CHEMICAL FORMULA: PROPRIETARY. ======================================================= Physical/Chemical Properties ======================================================= HCC: N1 Boiling Point: =100.C, 212.F Melt/Freeze Pt: =0.C, 32.F Solubility in Water: MISCIBLE Appearance and Odor: LIQUID, BROWN. CHARACTERISTIC. Percent Volatiles by Volume: ~95 ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: EXCESSIVE HEAT, LIGHT. Materials To Avoid: CONCENTRATED ACIDS. Hazardous Decomposition Products: MAY RELEASE IODINE VAPOR UNDER FIRE CONDITIONS. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NONE KNOWN ======================================================= Toxicological Information ======================================================= Toxicological Information: THRESHOLD LIMIT VALUE: N.E.-DO NOT INGEST. ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= Other Information: NFPA HAZARD RATINGS: HEALTH=1, FLAMMIBILITY=0, REACTIVITY=0. *N.E.=NOT ESTABLISHED. N.A.=NOT APPLICABLE. ======================================================= Transportation Information ======================================================= Responsible Party Cage: 57699 Trans ID NO: 157213 Product ID: AEROSPRAY GRAM REAGENT B, IODINE MSDS Prepared Date: 07/14/1994 Review Date: 06/01/2001 MFN: 1 Net Unit Weight: 1.057 LBS Multiple KIT Number: 0 Review IND: Y Unit Of Issue: BT Container QTY: 500.000 ML ======================================================= Detail DOT Information ======================================================= DOT PSN Code: ZZZ DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= Detail IMO Information ======================================================= IMO PSN Code: ZZZ IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION ======================================================= Detail IATA Information ======================================================= IATA PSN Code: ZZZ IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= Detail AFI Information ======================================================= AFI PSN Code: ZZZ AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= HAZCOM Label ======================================================= Product ID: AEROSPRAY GRAM REAGENT B, IODINE Cage: 57699 Company Name: WESCOR INC Street: 459 S MAIN ST City: LOGAN UT Zipcode: 84321-5207 Health Emergency Phone: 800-453-2725 Label Required IND: Y Date Of Label Review: 06/01/2001 Status Code: A Origination Code: F Eye Protection IND: YES Skin Protection IND: YES Signal Word: CAUTION Respiratory Protection IND: NO Health Hazard: Slight Contact Hazard: Slight Fire Hazard: None Reactivity Hazard: None Hazard And Precautions: SKIN EXPOSURE MAY CAUSE IRRITATION OR BURNS. CHRONIC EXPOSURE MAY CAUSE SKIN RASHES, RHINITIS, ASTHMA. LARGE QUANTITIES MAY BE FATAL IF SWALLOWED. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.