ORION RESEARCH -- REFERENCE ELECTRODE FILLING SOLUTION 4M KCL 900011 - INTERNAL FILLING SOLUTIONORION RESEARCH -- REFERENCE ELECTRODE FILLING SOLUTION 4M KCL 900011 - INTERNAL FILLING SOLUTION MATERIAL SAFETY DATA SHEET ORION RESEARCHNSN: 663000F013081 Manufacturer's CAGE: 30260 Part No. Indicator: A Part Number/Trade Name: REFERENCE ELECTRODE FILLING SOLUTION 4M KCL 900011 =========================================================================== General Information =========================================================================== Item Name: INTERNAL FILLING SOLUTION Company's Name: ORION RESEARCH INCORPORATED Company's Street: 829 MAIN STREET Company's City: BOSTON Company's State: MA Company's Country: US Company's Zip Code: 02129 Company's Emerg Ph #: 617-242-3900 Company's Info Ph #: 607-242-3900 Record No. For Safety Entry: 001 Tot Safety Entries This Stk#: 001 Status: SE Date MSDS Prepared: 12FEB88 Safety Data Review Date: 26JAN93 MSDS Preparer's Name: THOMAS F FLYNN Preparer's Company: ORION RESEARCH INCORPORATED Preparer's St Or P. O. Box: 829 MAIN STREET Preparer's City: BOSTON Preparer's State: MA Preparer's Zip Code: 02129 MSDS Serial Number: BJHBT =========================================================================== Ingredients/Identity Information =========================================================================== Proprietary: NO Ingredient: SILVER CHLORIDE Ingredient Sequence Number: 01 Percent: <1% NIOSH (RTECS) Number: VW3675000 CAS Number: 9007-35-6 ------------------------------------- Proprietary: NO Ingredient: POTASSIUM CHLORIDE Ingredient Sequence Number: 02 Percent: 29.8% NIOSH (RTECS) Number: TS8050000 CAS Number: 7447-40-7 ------------------------------------- Proprietary: NO Ingredient: WATER Ingredient Sequence Number: 03 Percent: 70% NIOSH (RTECS) Number: ZC0110000 CAS Number: 7732-18-5 =========================================================================== Physical/Chemical Characteristics =========================================================================== Appearance And Odor: COLORLESS, ODORLESS LIQUID. Boiling Point: 106C Melting Point: -6C Specific Gravity: 1.12 Solubility In Water: MISCIBLE pH: 5.5-8 =========================================================================== Fire and Explosion Hazard Data =========================================================================== Extinguishing Media: ANY SUITABLE FOR SURROUNDING AREA. Special Fire Fighting Proc: NONE, THIS SOLUTION IS NON-FLAMMABLE. =========================================================================== Reactivity Data =========================================================================== Stability: YES Hazardous Poly Occur: NO =========================================================================== Health Hazard Data =========================================================================== Route Of Entry - Inhalation: NO Route Of Entry - Skin: NO Route Of Entry - Ingestion: YES Health Haz Acute And Chronic: EYES: IRRITATION. SKIN: ITCHING, STINGING IN AN OPEN CUT. INGESTION: ELECTROLYTE IMBALANCE. Carcinogenicity - NTP: NO Carcinogenicity - IARC: NO Carcinogenicity - OSHA: NO Explanation Carcinogenicity: NONE Med Cond Aggravated By Exp: OPEN CUTS Emergency/First Aid Proc: SKIN: WASH OFF. EYES: IRRIGATE W/WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES. =========================================================================== Precautions for Safe Handling and Use =========================================================================== Steps If Matl Released/Spill: WASH DOWN DRAIN W/WATER. . Waste Disposal Method: WASH DOWN DRAIN W/WATER. DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, & FEDERAL REGULATIONS. Precautions-Handling/Storing: KEEP CLOSURE SEALED & STORE AT ROOM TEMPERATURE TO PROTECT PRODUCT INTEGRITY. AVOID CONTACT W/SKIN & EYES. SUITABLE FOR GENERAL STORAGE. =========================================================================== Control Measures =========================================================================== Ventilation: MECHANICAL (GENERAL) =========================================================================== Transportation Data =========================================================================== =========================================================================== Disposal Data =========================================================================== =========================================================================== Label Data =========================================================================== Label Required: YES Technical Review Date: 26JAN93 Label Date: 07JAN92 Label Status: F Common Name: REFERENCE ELECTRODE FILLING SOLUTION 4M KCL Chronic Hazard: NO Signal Word: CAUTION! Acute Health Hazard-Slight: X Contact Hazard-Slight: X Fire Hazard-None: X Reactivity Hazard-None: X Special Hazard Precautions: EYES: IRRITATION. SKIN: ITCHING, STINGING IN AN OPEN CUT. INGESTION: ELECTROLYTE IMBALANCE. Label Name: ORION RESEARCH INCORPORATED Label Street: 829 MAIN STREET Label City: BOSTON Label State: MA Label Zip Code: 02129 Label Country: US Label Emergency Number: 617-242-3900