CERTIFIED LABORATORIES; DIV OF NCH CORP -- SAF-SOL 20/20, 0135 -- 6850-00-551-3106 ===================== Product Identification ===================== Product ID:SAF-SOL 20/20, 0135 MSDS Date:03/07/1989 FSC:6850 NIIN:00-551-3106 MSDS Number: BKSRZ === Responsible Party === Company Name:CERTIFIED LABORATORIES; DIV OF NCH CORP Address:2730 CARL RD Box:152170 City:IRVING State:TX ZIP:75061 Country:US Info Phone Num:800-527-9929 Emergency Phone Num:214-438-1381, CHEMTREC 800-424-9300 Preparer's Name:CHANDA B HILL/TS CHEM CAGE:53417 === Contractor Identification === Company Name:CERTIFIED LABS DIV OF NCH CORP Box:152170 City:IRVING State:TX ZIP:75015 Country:US Phone:214-438-1381972-438-1381 CAGE:53417 ============= Composition/Information on Ingredients ============= Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III) CAS:71-55-6 RTECS #:KJ2975000 Fraction by Wt: 40% OSHA PEL:350 PPM/450 STEL ACGIH TLV:350 PPM/450STEL;9192 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ozone Depleting Chemical:1 Ingred Name:METHYLENE CHLORIDE (SARA III) CAS:75-09-2 RTECS #:PA8050000 Fraction by Wt: 40% OSHA PEL:500 PPM/C,1000; Z2 ACGIH TLV:50 PPM, A2; 9192 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:VM&P NAPHTHA (LIGROINE) CAS:8032-32-4 RTECS #:OI6180000 OSHA PEL:300 PPM/400 STEL ACGIH TLV:300 PPM; 9192 Ingred Name:SUPP DATA:CALL MD IMMED. NOTES TO MD:DEPENDING ON AMT INGEST/RETAINED AS WELL AS TOXICITY OF PRODUCT, GASTRIC(SEE ING 5) RTECS #:9999999ZZ Ingred Name:ING 4:LAVAGE SHOULD BE CONSIDERED. KEEP PATIENTS HEAD BELOW HIPS TO PREVENT PULMONARY ASPIRATION. IF COMATOSE(SEE ING 6) RTECS #:9999999ZZ Ingred Name:ING 5:A CUFFED ENDOTRACHEAL TUBE WILL PREVENT ASPIRATION. CONSULT A POISON CONTROL CENTER. RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:(ORAL RAT)10.300 MG/KG (INGREDIENT 2) Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:ACUTE:INHAL:CAN LEAD TO CNS DEPRESSION, CAN PRODUCE HDCH/DIZZ/NAUSEA AND LOSS OF COORDINATION AND CONSCIOUSNESS. SKIN:DEFAT & IRRIT. EYE:IRRIT/TEARS/REDNESS. INGEST:NAUSEA/DIZZ/ VOMIT/POSSIBLE LOSS OF CONSCIOUSNESS. CHRONIC:CNS DEPRESS/KIDNEY DMG/DERM/LIVER DMG. SYSTEMIC & OTHER EFTS:EXCESSIVE EXPO(SEE EFTS OF OVEREXP) Explanation of Carcinogenicity:METHYLENE CHLORIDE:GROUP 2B (IARC), GROUP 2 (NTP). Effects of Overexposure:HLTH HAZ:MAY CAUSE CNS/LIVER/KIDNEY EFTS. METHYLENE CHLORIDE HAS BEEN SHOWN TO INCREASE THE RATE OF SPONTANEOUSLY OCCURING MALIGNANT TUMORS IN LAB RATS. OTHER ANIMAL STUDIES AND SEVERAL HUMAN EPIDEMOL OGY STUDIES, FAILED TO SHOW TUMORIGENICRESPONSE RELATABLE TO METHYLENE CHLORIDE. IT IS NOT BELIEVED TO POSE (SUPP DATA) Medical Cond Aggravated by Exposure:PEOPLE AFFECTED WITH SKIN, KIDNEY, LIVER, RESPIRATORY SYSTEM AND CENTRAL NERVOUS SYSTEM DISEASE. ======================= First Aid Measures ======================= First Aid:INHAL:REMOVE TO FRESH AIR AND TREAT SYMPTOMATICALLY. GIVE O*2 IF BRTHNG IS DIFFICULT. GIVE ART RESP IF BRTHNG STOPS. GET MD IMMED. EYE:FLUSH W/WATER FOR AT LEAST 15 MINS. CALL MD IF IRRIT PERSISTS. SK IN:WASH W/SOAP & WATER. APPLY EMOLIENT RICH CREAM. CALL MD IF IRRIT PERSISTS. INGEST:DO NOT INDUCE VOMITING, EVEN IF IT OCCURS. IF OCCURS, KEEP HEAD BELOW HIPS TO PREVENT ASPIRATION OF LIQ (SUPP DATA) ===================== Fire Fighting Measures ===================== Flash Point Method:TOC Flash Point:185F,85C Extinguishing Media:FOAM, CO*2, DRY CHEMICAL AND WATER SPRAY. Fire Fighting Procedures:A NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:PHOSGENE CAN BE PRODUCED. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL . ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE ALL SOURCES OF IGNITON. PREVENT FROM ENTERING SEWER OR WATER SOURCES. VENTILATE ENCLOSED SPACES OR WEAR NIOSH/MSHA APPRVD RESP FOR PROT. CLEANUP:PUMP UP (EXPLO PROOF MOTORS), OR SOAK UP W/SAND, COTTON WASTES OR OTHER ABSORBANT. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STOR TEMP: -50F MIN, 120F MAX. STORE INDOORS/OUTDOORS ON SIDE. STORE IN ORIGINAL CONTAINER ONLY. FOLLOW LABEL DIRECTIONS. Other Precautions:KEEP AWAY FROM CHILDREN. NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSG ENE . ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NO RESP NEEDED IN NORMAL USE. IN EMERGENCY SITUATIONS, THE FOLLOWING NIOSH/MSHA APPROVED RESPIRATORS ARE RECOMMENDED:500 PPM: SAF/SCAF. ESCAPE:GMOV/SCBA. Ventilation:SUFFICIENT VENTILATION TO BE BELOW ALLOWABLE CONCENTRATION. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:APRON WHEN SPRAYING. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health EFTS OF OVEREXP:A MEASURABLE CARCINOGENIC RISK TO MAN WHEN HANDLED AS RECOMMENDED. BIRTH DEFECTS ARE UNLIKELY. EXPOS HAVING NO EFFECT ON FETUS. DID NOT CAUSE BIRTH DEFECTS IN ANIMALS. OTHER EFFECTS WE RE SEEN IN THE FETUS ONLY AT DOSES WHICH CAUSED TOXIC EFFECTS TO THE MOTHER. FIRST AID PROC:INTO LUNGS. (SEE INGRED 4) ================== Physical/Chemical Properties ================== HCC:T6 Boiling Pt:B.P. Text:113F,45C Vapor Pres:120 Vapor Density:1 Spec Gravity:0.986 Solubility in Water:NEGLIGIBLE Appearance and Odor:CLEAR, SWEET SOLVENT Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG ACIDS, BASES AND SELECTED AMINES. ALSO ALUMINUM. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:CAN AT DECOMP TEMP RELEASE CO*2 OR CO, PHOSGENE, AND HYDROGEN CHLORIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:THE WASTE LIQUIDS SHOULD BE SENT TO A LICENCED RECLAIMER OR INCINERATED AT A LICENCED INCINERATOR. ALSO THE SPILLED SOLVENT AND ABSORBANT WIPING MATERIAL SHOULD BE DISPOSED OF IN A WASTE MANAGEMENT FA CILITY LICENSED FOR THIS PURPOSE. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.