BIO-RAD LABORATORIES CLINICAL -- 1610800 TEMED 5 ML ======================================================= MSDS Safety Information ======================================================= FSC: 6850 MSDS Date: 01/22/1997 MSDS Num: CGHKX LIIN: 00F054590 Product ID: 1610800 TEMED 5 ML MFN: 01 Responsible Party Cage: 10987 Name: BIO-RAD LABORATORIES CLINICAL DIV Address: 2000 ALFRED NOBEL DR City: HERCULES CA 94547-5000 Info Phone Number: 510-724-7000/510-741-1000 Emergency Phone Number: 510-724-7000/510-741-1000 Review Ind: Y Published: Y ======================================================= Preparer Co. when other than Responsible Party Co. ======================================================= Cage: 10987 Name: BIO-RAD LABORATORIES Address: 3300 REGATTA BLVD City: RICHMOND CA 94804 ======================================================= Contractor Summary ======================================================= Cage: 10987 Name: BIO-RAD LABORATORIES Address: 3300 REGATTA BLVD City: RICHMOND CA 94804 Phone: 415-232-7000 ======================================================= Ingredients ======================================================= Cas: 110-18-9 RTECS #: KV7175000 Name: N,N,N',N'-TETRAMETHYLETHYLENEDIAMINE ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: ORAL LD50(RAT): 1580 MG/KG Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: SKIN: CAUSTIC EFFECT. EYES: STRONG CAUSTIC EFFECT. INHALATION: WILL LEAD TO A STRONG CAUSTIC EFFECT TO THE MUCOUS MEMBRANE, MOUTH & THROAT. INGESTION: DANGER TO PERFORATION OF THE ESOPHAGUS & STOMACH. CAUSES BURNS. Explanation Of Carcinogenicity: NONE Signs And Symptions Of Overexposure: SKIN: CAUSTIC EFFECT. EYES: STRONG CAUSTIC EFFECT. INHALATION: WILL LEAD TO A STRONG CAUSTIC EFFECT TO THE MUCOUS MEMBRANE, MOUTH & THROAT. INGESTION: DANGER TO PERFORATION OF THE ESOPHAGUS & STOMACH. CAUSES BURNS. First Aid: INHALATION: REMOVE TO FRESH AIR. GIVE CPR & KEEP WARM. IF UNCONSCIOUS, PLACE PATIENT STABLY IN SIDE POSITION FOR TRANSPORTATION. SKIN: WASH W/WATER & SOAP & RINSE THOROUGHLY. EYES: RINSE FOR SEVERAL MINS UNDER RUNNING WATER. INGESTION: DRIN K COPIOUS AMOUNTS OF WATER & GIVE FRESH AIR. OBTAIN MEDICAL ATTENTION IN ALL CASES. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: WEAR PROTECTIVE EQUIPMENT. EVACUATE AREA. PREVENT SEEPAGE INTO SEWAGE SYSTEM, WORKPITS & CELLARS. ABSORB W/LIQUID-BINDING MATERIAL. USE NEUTRALIZING AGENT. Waste Disposal Methods: DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS. MUSTN'T BE DISPOSED OF TOGETHER W/HOUSEHOLD GARBAGE. DON'T ALLOW PRODUCT TO REACH SEWAGE SYSTEM. FLAMMABLE LIQUIDS UN2372. Handling And Storage Precautions: STORE IN COOL, DRY CONDITIONS IN WELL SEALED RECEPTACLES. KEEP RECEPTACLES TIGHTLY SEALED. KEEP IGNITION SOURCES AWAY. Other Precautions: DON'T SMOKE. PROTECT AGAINST ELECTROSTATIC CHARGES.ENSURE GOOD VENTILATION/EXHAUSTION AT THE WORKPLACE. AVOID CONTACT W/EYES &SKIN. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: 69.8F Lower Limits: 9.08 Upper Limits: 0.98 Extinguishing Media: CO2, EXTINGUISHING POWDER/WATER SPRAY. LARGE FIRES: WATER SPRAY/ALCOHOL RESISTANT FOAM. Fire Fighting Procedures: USE WATER W/FULL JET & MOUNT RESPIRATORY PROTECTIVE DEVICE. ======================================================= Control Measures ======================================================= Respiratory Protection: IN CASE OF BRIEF EXPOSURE/LOW POLLUTION USE RESPIRATORY FILTER DEVICE. IN CASE OF INTENSIVE/LONGER EXPOSURE USE RESPIRATORY PROTECTIVE DEVICE THAT IS INDEPENDENT OF CIRCULATING AIR. Ventilation: ADEQUATE Protective Gloves: SYNTHETIC Eye Protection: TIGHTLY SEALED GOGGLES Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. WASH HANDS BEFORE BREAKS & AT THE END OF WORK. Supplemental Safety and Health: KEEP AWAY FROM FOODSTUFFS, BEVERAGES & FEED. ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: 244.4F Solubility in Water: MISCIBLE Appearance and Odor: LIGHT YELLOW FLUID W/AMINE-LIKE ODOR ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Hazardous Polymerization Indicator: NO ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= HAZCOM Label ======================================================= Product ID: 1610800 TEMED 5 ML Cage: 10987 Company Name: BIO-RAD LABORATORIES Street: 3300 REGATTA BLVD City: RICHMOND CA Zipcode: 94804 Health Emergency Phone: 510-724-7000/510-741-1000 Label Required IND: Y Date Of Label Review: 10/12/1999 Status Code: A Origination Code: G Hazard And Precautions: SKIN: CAUSTIC EFFECT. EYES: STRONG CAUSTIC EFFECT. INHALATION: WILL LEAD TO A STRONG CAUSTIC EFFECT TO THE MUCOUS MEMBRANE, MOUTH & THROAT. INGESTION: DANGER TO PERFORATION OF THE ESOPHAGUS & STOMACH. CAUSES BURNS. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.