MONSANTO CO -- SANTOVAC 5 VACUUM PUMP FLUID ======================================================= MSDS Safety Information ======================================================= FSC: 9150 NIIN: 01-337-8179 MSDS Date: 06/12/1995 MSDS Num: CFWSL Product ID: SANTOVAC 5 VACUUM PUMP FLUID MFN: 02 Responsible Party Cage: 76541 Name: MONSANTO CO Address: 800 N LINDBERGH BLVD City: ST LOUIS MO 63167 Info Phone Number: 314-694-6661 Emergency Phone Number: 800-424-9300(CHEMTREC) Proprietary Ind: Y Published: Y ======================================================= Contractor Summary ======================================================= Cage: 76541 Name: MONSANTO COMPANY Address: 800 N LINDBERGH BLVD City: ST LOUIS MO 63167 Phone: 314-694-6661 OR 800-332-3111 ======================================================= Item Description Information ======================================================= Item Name: LUBRICATING OIL,AIRCRAFT TURBINE ENGINE,PETROLEUM ======================================================= Ingredients ======================================================= Name: *** PROPRIETARY *** ----------------------------- ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: LD50 (ORAL, RAT): >10,000 MG/KG Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: NO SIGNIFICANT HAZ ASSOCD W/THIS MATL. OCCUP EXPOS TO THIS MATL HAS NOT BEEN RPTD TO CAUSE SIGNIFICANT ADVERSE HLTH EFTS. ON THE BASIS OF AVAIL INFO, EXPOS TO SANTOVAC 5 VACUUM PUMP FLUID IS NOT EXPECTED TO PRDCE SIGNIFICANT ADVERSE HUMAN H LTH EFTS WHEN REC SAFETY PRECS ARE FOLLOWED. TOXICOLOGICAL (EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT. Signs And Symptions Of Overexposure: HLTH HAZ:INFO:IN A CONTROLLED SKIN CONTACT STUDY, NO SKIN IRRITATION (PRIMARY/CUMULATIVE)/SKIN ALLERGY WAS OBSERVED IN HUMANS FOLLOWING RPTD EXPOS TO A POLYPHENYL ETHER FORMULATION SIMILAR TO SANTOVAC 5 VACUUM PUMP FLUID. INCRS IN LIVER WEI GHTS & LIVER/BODY WEIGHT RATIOS W/ACCOMPANYING INCR IN LIVER (SUPDAT) Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER. First Aid: EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD (FP N). SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD (FP N). WASH HEAVILY CONTAMINATED CLOTHING BEFORE REUSE. INHAL:REMOVE TO FRESH AIR. REMOVE MA TERIAL FROM EYES, SKIN AND CLOTHING. INGEST:A PHYSICIAN OR POISON CONTROL CENTER CAN BE CONTACTED FOR ADVICE. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: CONTAIN LARGE SPILLS W/DIKES & TRANSFER THE MATL TO APPROPRIATE CNTNRS FOR RECLAMATION/DISPOSAL. ABSORB REMAINING MATERIAL/SMALL SPILLS WITH AN INERT MATERIAL AND THEN PLACE IN A CHEMICAL WASTE CONTAINER. FLUSH RESIDUAL SPILL AREA WITH WATE R. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: PROD TO BE DISPOSED OF, SPILLED LIQ PROD/SPILLS ABSORBED ON A SOLID MEDIUM MAY BE CLASSIFIED AS "HAZ WASTE" (DO18) DUE TO THE PRESENCE OF BENZENE OVER 0.5 MG/L. WASTE SHOULD BE ANALYZED I/A/W/METHOD 1311 TOXICITY CHARACTERISTIC LEACHING (IN G 4) Handling And Storage Precautions: HANDLE I/A/W/GOOD INDUS HYGIENE & SAFETY PRACTICES. THESE PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE & REMOVE OF MATL FROM EYES, SKIN & CLOTHING. Other Precautions: EMPTIED CONTAINER RETAINS VAPOR AND PRODUCT RESIDUE.OBSERVE ALL LABELED SAFEGUARDS UNTIL CONTAINER IS CLEANED, RECONDITIONED,OR DESTROYED. PRODUCT IS STABLE UNDER NORMAL CONDITIONS OF STORAGE ANDHANDLING. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Method: COC Flash Point Text: 550F,288C Extinguishing Media: IN CASE OF FIRE, USE WATER SPRAY (FOG), FOAM, DRY CHEMICAL, OR CO*2. Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N). FIRE FIGHTING EQUIPMENT SHOULD BE THOROUGHLY DECONTAMINATED AFTER USE. Unusual Fire/Explosion Hazard: NONE KNOWN. ======================================================= Control Measures ======================================================= Respiratory Protection: AVOID BRTHG MIST. USE NIOSH APPRVD RESP PROT EQUIP WHEN AIRBORNE EXPOS IS EXCESSIVE. CONSULT RESP MFR TO DETERM APPROP TYPE EQUIP FOR GIVEN APPLICATION. OBSERVE RESP USE LIMITATION SPECIFIED BY NIOSH/MFR. RESP PROT PROGRAMS MUST Ventilation: PROVIDE NATURAL/MECH VENT TO MINIMIZE EXPOS. IF PRACTICAL, USE LOCAL MECH EXHST VENT AT SOURCES OF AIR Protective Gloves: IMPERVIOUS GLOVES (FP N). Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N). Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). Work Hygienic Practices: WASH HANDS AND CONTAMINATED SKIN THOROUGHLY AFTER HANDLING. Supplemental Safety and Health: USERS OF "L" VERSION OF SHOULD CONSULT "LR" VERSION FOR ADDITIONAL INFO (FP N). SPEC GRAV:1.195-1.201 @ 25/25C. PH:NEUTRAL. SOL IN H*2O:SOLUBLE IN ACETONE AND LIGHT AROMATIC SOLVENTS; INSOLUBLE IN WATER. EFTS OF OVEREXP:CELL SIZE, CONS IDERED TO BE RELEATED TO INCREASED LIVER METHABOLIC ACTIVITY & ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: 889F,476C Vapor Density: 15.5 Spec Gravity: SUPDAT PH: SUPDAT Solubility in Water: SUPDAT Appearance and Odor: LIGHT YELLOW ESSENTIALLY CLEAR LIQUID; ODORLESS TO SLIGHT PHENOLIC ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER. Materials To Avoid: EXPOSURE TO HIGHLY OXIDIZING AGENTS SHOULD BE AVOIDED. Hazardous Decomposition Products: CONTINUED USE AT TEMP AVOVE 425C MAY RSLT IN THE FORMATING OF BENZENE & PHENOL. IF THE PROD IS BURNED, COMPLETE Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT. ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= Transportation Information ======================================================= Responsible Party Cage: 76541 Trans ID NO: 127023 Product ID: SANTOVAC 5 VACUUM PUMP FLUID MSDS Prepared Date: 06/12/1995 Review Date: 02/23/1998 MFN: 2 Multiple KIT Number: 0 Review IND: Y ======================================================= Detail DOT Information ======================================================= DOT PSN Code: ZZZ DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= Detail IMO Information ======================================================= IMO PSN Code: ZZZ IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION ======================================================= Detail IATA Information ======================================================= IATA PSN Code: ZZZ IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= Detail AFI Information ======================================================= AFI PSN Code: ZZZ AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION ======================================================= HAZCOM Label ======================================================= Product ID: SANTOVAC 5 VACUUM PUMP FLUID Cage: 76541 Company Name: MONSANTO COMPANY Street: 800 N LINDBERGH BLVD City: ST LOUIS MO Zipcode: 63167 Health Emergency Phone: 800-424-9300(CHEMTREC) Label Required IND: Y Date Of Label Review: 12/04/1997 Status Code: C Label Date: 12/04/1997 Origination Code: G Eye Protection IND: YES Skin Protection IND: YES Signal Word: CAUTION Respiratory Protection IND: YES Health Hazard: None Contact Hazard: None Fire Hazard: Slight Reactivity Hazard: None Hazard And Precautions: COMBUSTIBLE. ACUTE & CHRONIC: NONE SPECIFIED BY MANUFACTURER. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.