NU-CALGON WHOLESALER INC -- DEGREASING SOLVENT, 4161 ======================================================= MSDS Safety Information ======================================================= FSC: 7930 MSDS Date: 04/11/1991 MSDS Num: CBCNJ LIIN: 00N064933 Product ID: DEGREASING SOLVENT, 4161 MFN: 01 Responsible Party Cage: 0XX75 Name: NU-CALGON WHOLESALER INC Address: 2451 SCHUETZ RD City: MARYLAND HEIGHTS MO 63043 Info Phone Number: 314-994-1010; 800-354-3499 Emergency Phone Number: 800-424-9300(CHEMTREC) Published: Y ======================================================= Contractor Summary ======================================================= Cage: 0XX75 Name: NU-CALGON WHOLESALER, INC. Address: 2008 ALTOM COURT City: ST LOUIS MO 63146-4151 Phone: 800-554-5499/314-469-7000 ======================================================= Ingredients ======================================================= Cas: 8052-41-3 RTECS #: WJ8925000 Name: STODDARD SOLVENT. LD50:(ORAL,RAT) >10 MG/KG. % Wt: 60 OSHA PEL: 500 PPM ACGIH TLV: 100 PPM ------------------------------ Cas: 71-55-6 RTECS #: KJ2975000 Name: ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA 313) (CERCLA) % Wt: 40 OSHA PEL: 350 PPM ACGIH TLV: 350 PPM;450 STEL EPA Rpt Qty: 1000 LBS DOT Rpt Qty: 1000 LBS Ozone Depleting Chemical: 1 ======================================================= Health Hazards Data ======================================================= LD50 LC50 Mixture: SEE INGREDIENT 1. Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: ACUTE:EYES/SKIN:CAUSES IRRIT. MAY DEFAT, DRY & CAUSE SCALING OF SKIN UPON EXPOS. INHAL:HARMFUL IF INHALED. MAY CAUSE NAUS, VOMIT, COUGH & RESP IRRIT. INGEST:ASPIR INTO LUNGS CAN OCCUR RESULTING IN PNEUMONITIS, PULM EDEMA & HEMORRHAGE. CHRON IC:INHAL OF STODDARD SOLV SHOW RSLTS OF HEPATIC & (EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT Signs And Symptions Of Overexposure: HLTH HAZ:HEMATOPOIETIC CHANGES. CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES I N HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS (FP N). Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER. First Aid: EYES:IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. CALL MD. SKIN:FLUSH W/WATER. WASH CLOTHING BEFORE REUSE. INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTF RESP, PREFERABLY MOUTH TO MOUTH. IF BREATHING IS DIFFICULT, GI VE OXYGEN. CALL MD. INGEST:DO NOT INDUCE VOMITING. CALL MD IMMEDIATELY. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: DIKE AREA, CONTAIN AS MUCH SPILLED MATERIAL POSSIBLE. REMOVE ANY REMAINING MATERIAL BY ABSORBING ON VERMICULITE OR OTHER SUITABLE ABSORBING MATERIAL. DISPOSE OF IN AN APPROVED LANDFILL. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: DISPOSE OF I/A/W ABOVE DESCRIBED (OR SIMILARLY APPROVED) DISPOSAL PROCUDURE. DISPOSE OF I/A/W LOCAL, STATE & FEDERAL REGULATIONS. Handling And Storage Precautions: AVOID CONTACT W/EYES, SKIN & CLTHG. AVOID BREATHING VAPORS. KEEP CNTNR CLOSED. VAPORS ARE HVR/AIR & WILL COLLECT IN LOW AREAS. Other Precautions: USE ONLY IN WELL-VENTILATED AREAS THAT WILL MAINTAIN AIRLEVELS BELOW LIMS ESTABLISHED BY FED, STATE & LOC REGS. NO SMOKING IN AREAOF USE. DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT&/OR UV RADIA MAY CAUSE (SUPDAT) ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Method: TOC Flash Point Text: 116F,47C Extinguishing Media: DRY CHEMICAL, FOAM, CO*2. Fire Fighting Procedures: USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT (FP N). EXERCISE CAUTION WHEN FIGHTING ANY CHEMICAL FIRE. Unusual Fire/Explosion Hazard: THERMAL DECOMP PRODS MAY INCL HCL & PHOSGENE (FP N). TOX GASES & VAPS SUCH AS HYDROGEN CHLORIDE, PHOSGENE & CARBON MONOXIDE MAY BE RELEASED IF INVOLVED IN FIRE. ======================================================= Control Measures ======================================================= Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR IS RECOMMENDED IF EXCEEDS OSHA TLV'S FOR STODDARD SOLVENT & 1,1,1-TRICHLOROETHANE. Ventilation: LOCAL & MECHANICAL EXHAUST IS RECOMMENDED. Protective Gloves: SOLVENT-RESISTANT RUBBER GLOVES. Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N). Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). Work Hygienic Practices: WASH THOROUGHLY AFTER HANDLING. Supplemental Safety and Health: % VOLAT:100 (WT). OTHER PREC:FORMATION OF HCL &/OR PHOSGENE (FP N). ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: 165F,74C Spec Gravity: 0.982 (H*2O=1) Solubility in Water: SLIGHT Appearance and Odor: CLEAR LIQUID; HYDROCARBON ODOR. Percent Volatiles by Volume: SUPDAT ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: KEEP AWAY FROM HEAT & FLAME. Materials To Avoid: STRONG OXIDIZERS, ALUMINUM & MAGNESIUM POWDERS & SODIUM & POTASSIUM. Hazardous Decomposition Products: TOXIC GASES & VAPORS SUCH AS HYDROGEN CHLORIDE, PHOSGENE & CARBON MONOXIDE MAY BE RELEASED IF INVOLVED IN A FIRE. Hazardous Polymerization Indicator: NO Conditions To Avoid Polymerization: NOT RELEVANT ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= HAZCOM Label ======================================================= Product ID: DEGREASING SOLVENT, 4161 Cage: 0XX75 Company Name: NU-CALGON WHOLESALER, INC. Street: 2008 ALTOM COURT City: ST LOUIS MO Zipcode: 63146-4151 Health Emergency Phone: 800-424-9300(CHEMTREC) Label Required IND: Y Date Of Label Review: 11/13/1995 Status Code: C Label Date: 11/13/1995 Origination Code: G Chronic Hazard IND: Y Eye Protection IND: YES Skin Protection IND: YES Signal Word: WARNING Respiratory Protection IND: YES Health Hazard: Moderate Contact Hazard: Slight Fire Hazard: Moderate Reactivity Hazard: None Hazard And Precautions: COMBUSTIBLE. ACUTE:INHALATION OF VAPORS MAY CONTRIBUTE TO THE OCCURRENCE OF IRREGULAR HEARTBEAT (FP N). EYES OR SKIN:CAUSES IRRITATION. MAY DEFAT, DRY & CAUSE SCALING OF SKIN UPON EXPOSURE. INHALATION:HARMFUL IF INHALED. MAY CAUSE NAUSEA, V OMITING, COUGHING & RESPIRATORY IRRITATION. INGESTION:ASPIRATION INTO LUNGS CAN OCCUR RESULTING IN PNEUMONITIS, PULMONARY EDEMA & HEMORRHAGE. CHRONIC:INHALATION OF STODDARD SOLVENT SHOW RESULTS OF HEPATIC & BLOOD FORMATION CHANGES. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.